High angular resolution diffusion imaging reveals intravoxel white matter fiber heterogeneity

被引:1194
作者
Tuch, DS
Reese, TG
Wiegell, MR
Makris, N
Belliveau, JW
Wedeen, VJ
机构
[1] Massachusetts Gen Hosp, Athinoula A Martinos Ctr Biomed Imaging, Charlestown, MA 02129 USA
[2] Massachusetts Gen Hosp, Ctr Morphometr Anal, Charlestown, MA 02129 USA
关键词
diffusion; diffusion-weighted MRI (DWI); diffusion tensor imaging (DTI); white matter; tractography;
D O I
10.1002/mrm.10268
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnetic resonance (MR) diffusion tensor imaging (DTI) can resolve the white matter fiber orientation within a voxel provided that the fibers are strongly aligned. However, a given voxel may contain a distribution of fiber orientations due to, for example, intravoxel fiber crossing. The present study sought to test whether a geodesic, high b-value diffusion gradient sampling scheme could resolve multiple fiber orientations within a single voxel. In regions of fiber crossing the diffusion signal exhibited multiple local maxima/minima as a function of diffusion gradient orientation, indicating the presence of multiple intravoxel fiber orientations. The multimodality of the observed diffusion signal precluded the standard tensor reconstruction, so instead the diffusion signal was modeled as arising from a discrete mixture of Gaussian diffusion processes in slow exchange, and the underlying mixture of tensors was solved for using a gradient descent scheme. The multitensor reconstruction resolved multiple intravoxel fiber populations corresponding to known fiber anatomy. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:577 / 582
页数:6
相关论文
共 33 条
[1]   Analysis of partial volume effects in diffusion-tensor MRI [J].
Alexander, AL ;
Hasan, KM ;
Lazar, M ;
Tsuruda, JS ;
Parker, DL .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (05) :770-780
[2]  
Basser PJ, 2000, MAGNET RESON MED, V44, P625, DOI 10.1002/1522-2594(200010)44:4<625::AID-MRM17>3.0.CO
[3]  
2-O
[4]   MR DIFFUSION TENSOR SPECTROSCOPY AND IMAGING [J].
BASSER, PJ ;
MATTIELLO, J ;
LEBIHAN, D .
BIOPHYSICAL JOURNAL, 1994, 66 (01) :259-267
[5]   ESTIMATION OF THE EFFECTIVE SELF-DIFFUSION TENSOR FROM THE NMR SPIN-ECHO [J].
BASSER, PJ ;
MATTIELLO, J ;
LEBIHAN, D .
JOURNAL OF MAGNETIC RESONANCE SERIES B, 1994, 103 (03) :247-254
[6]   NUCLEAR MAGNETIC-RESONANCE MEASUREMENT OF SKELETAL-MUSCLE - ANISOTROPY OF DIFFUSION-COEFFICIENT OF INTRACELLULAR WATER [J].
CLEVELAND, GG ;
CHANG, DC ;
HAZLEWOOD, CF ;
RORSCHACH, HE .
BIOPHYSICAL JOURNAL, 1976, 16 (09) :1043-1053
[7]   Tracking neuronal fiber pathways in the living human brain [J].
Conturo, TE ;
Lori, NF ;
Cull, TS ;
Akbudak, E ;
Snyder, AZ ;
Shimony, JS ;
McKinstry, RC ;
Burton, H ;
Raichle, ME .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1999, 96 (18) :10422-10427
[8]   MAXIMUM LIKELIHOOD FROM INCOMPLETE DATA VIA EM ALGORITHM [J].
DEMPSTER, AP ;
LAIRD, NM ;
RUBIN, DB .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES B-METHODOLOGICAL, 1977, 39 (01) :1-38
[9]   ANISOTROPY OF WATER DIFFUSION IN THE MYOCARDIUM OF THE RAT [J].
GARRIDO, L ;
WEDEEN, VJ ;
KWONG, KK ;
SPENCER, UM ;
KANTOR, HL .
CIRCULATION RESEARCH, 1994, 74 (05) :789-793
[10]  
Jones DK, 1999, MAGN RESON MED, V42, P37, DOI 10.1002/(SICI)1522-2594(199907)42:1<37::AID-MRM7>3.0.CO