Scatter compensation methods in 3D iterative SPECT reconstruction: A simulation study

被引:75
作者
Beekman, FJ
Kamphuis, C
Frey, EC
机构
[1] UNIV N CAROLINA,DEPT BIOMED ENGN,CHAPEL HILL,NC 27599
[2] UNIV N CAROLINA,DEPT RADIOL,CHAPEL HILL,NC 27599
关键词
D O I
10.1088/0031-9155/42/8/011
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Effects of different scatter compensation methods incorporated in fully 3D iterative reconstruction are investigated. The methods are: (i) the inclusion of an 'ideal scatter estimate' (ISE); (ii) like (i) but with a noiseless scatter estimate (ISE-NF); (iii) incorporation of scatter in the point spread function during iterative reconstruction ('ideal scatter model', ISM); (iv) no scatter compensation (NSC); (v) ideal scatter rejection (ISR), as can be approximated by using a camera with a perfect energy resolution. The iterative method used was an ordered subset expectation maximization (OS-EM) algorithm. A cylinder containing small cold spheres was used to calculate contrast-to-noise curves. For a brain study, global errors between reconstruction and 'true' distributions were calculated. Results show that ISR is superior to all other methods. In all cases considered, ISM is superior to ISE and performs approximately as well as (brain study) or better than (cylinder data) ISE-NF. Both ISM and ISE improve contrast-to-noise curves and reduce global errors, compared with NSC. In the case of ISE, blurring of the scatter estimate with a Gaussian kernel results in slightly reduced errors in brain studies, especially at low count levels. The optimal Gaussian kernel size is strongly dependent on the noise level.
引用
收藏
页码:1619 / 1632
页数:14
相关论文
共 33 条
[1]   SPECT scatter modelling in non-uniform attenuating objects [J].
Beekman, FJ ;
denHarder, JM ;
Viergever, MA ;
vanRijk, PP .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (06) :1133-1142
[2]   FAST SPECT SIMULATION INCLUDING OBJECT SHAPE DEPENDENT SCATTER [J].
BEEKMAN, FJ ;
VIERGEVER, MA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1995, 14 (02) :271-282
[3]   OBJECT SHAPE DEPENDENT PSF MODEL FOR SPECT IMAGING [J].
BEEKMAN, FJ ;
EIJKMAN, EGJ ;
VIERGEVER, MA ;
BORM, GF ;
SLIJPEN, ETP .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (01) :31-39
[4]   A NEW PHANTOM FOR FAST DETERMINATION OF THE SCATTER RESPONSE OF A GAMMA-CAMERA [J].
BEEKMAN, FJ ;
FREY, EC ;
KAMPHUIS, C ;
TSUI, BMW ;
VIERGEVER, MA .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) :1481-1488
[5]   Improved SPECT quantitation using fully three-dimensional iterative spatially variant scatter response compensation [J].
Beekman, FJ ;
Kamphuis, C ;
Viergever, MA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1996, 15 (04) :491-499
[6]  
BOWSHER JE, 1991, J NUCL MED, V32, P1285
[7]   Bayesian reconstruction and use of anatomical a Priori information for emission tomography [J].
Bowsher, JE ;
Johnson, VE ;
Turkington, TG ;
Jaszczak, RJ ;
Floyd, CE ;
Coleman, RE .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1996, 15 (05) :673-686
[8]   SCATTER CORRECTION IN SCINTIGRAPHY - THE STATE-OF-THE-ART [J].
BUVAT, I ;
BENALI, H ;
TODDPOKROPEK, A ;
DIPAOLA, R .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1994, 21 (07) :675-694
[9]   Block-iterative methods for image reconstruction from projections [J].
Byrne, CL .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 1996, 5 (05) :792-794
[10]   SPACE-ALTERNATING GENERALIZED EXPECTATION-MAXIMIZATION ALGORITHM [J].
FESSLER, JA ;
HERO, AO .
IEEE TRANSACTIONS ON SIGNAL PROCESSING, 1994, 42 (10) :2664-2677