Dehumidification in greenhouses by condensation on finned pipes

被引:25
作者
Campen, JB
Bot, GPA
机构
[1] IMAG, NL-6700 AA Wageningen, Netherlands
[2] Univ Wageningen & Res Ctr, Dept Agr Environm & Syst Engn, NL-6703 HD Wageningen, Netherlands
关键词
D O I
10.1006/bioe.2002.0058
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
In this study, an experimental dehumidifying system for greenhouses is tested. The system uses finned pipes fixed under the gutter of the greenhouse. The pipes are cooled below the dewpoint of the greenhouse air by cold water. The humid air passes the pipe and fins by natural convection and condensation occurs reducing the humidity in the greenhouse. The performance of the system in relation to its location and dimensions are studied by computational fluid dynamics calculations. The total heat transferred and condensate removed are monitored as a function of the greenhouse conditions. The system removes 40 g of condensate per hour per square metre of greenhouse floor from the humid air sufficient during periods when heating is applied and ventilation is minimized. The heat transferred at the cold surface by condensation is less than one-third of the total heat removed by the system at a relative humidity of 80%. (C) 2002 Silsoe Research Institute. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:177 / 185
页数:9
相关论文
共 7 条
[1]  
Bakker J.C., 1991, THESIS WAGENINGEN U
[2]  
BECKER M, 1986, HEAT TRANSFER
[3]  
CAMPEN JB, 2001, J AGR ENG RES, V28, P65, DOI DOI 10.1006/JAER20000633
[4]  
DeZwart HF, 1997, NETH J AGR SCI, V45, P97
[5]  
*FLUENT INC, 1998, FLUENT 5 US GUID
[6]  
*TNO, 1996, 96CONR1584 TNO
[7]  
WEAST RC, 1981, CRC HDB CHEM PHYSICS