Quantification of wall shear stress in large blood vessels using lagrangian interpolation functions with cine phase-contrast magnetic resonance imaging

被引:87
作者
Cheng, CP
Parker, D
Taylor, CA
机构
[1] Stanford Univ, Dept Mech Engn, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Surg, Stanford, CA 94305 USA
关键词
atherosclerosis; hemodynamics; cine phase contrast; pulsatile flow;
D O I
10.1114/1.1511239
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Arterial wall shear stress is hypothesized to be an important factor in the localization of atherosclerosis. Current methods to compute wall shear stress from magnetic resonance imaging (MRI) data do not account for flow profiles characteristic of pulsatile flow in noncircular vessel lumens. We describe a method to quantify wall shear stress in large blood vessels by differentiating velocity interpolation functions defined using cine phase-contrast MRI data on a band of elements in the neighborhood of the vessel wall. Validation was performed with software phantoms and an in vitro flow phantom. At an image resolution corresponding to in vivo imaging data of the human abdominal aorta, time-averaged, spatially averaged wall shear stress for steady and pulsatile flow were determined to be within 16% and 23% of the analytic solution, respectively. These errors were reduced to 5% and 8% with doubling in image resolution. For the pulsatile software phantom, the oscillation in shear stress was predicted to within 5%. The mean absolute error of-circumferentially resolved shear stress for the nonaxisymmetric phantom decreased from 28% to 15% with a doubling in image resolution. The irregularly shaped phantom and in, vitro investigation demonstrated convergence of the calculated values with increased image resolution. We quantified the shear stress at the supraceliac and infrarenal regions of a human abdominal aorta to be 3.4 and 2.3 dyn/cm(2), respectively. (C) 2002 Biomedical Engineering Society.
引用
收藏
页码:1020 / 1032
页数:13
相关论文
共 32 条
  • [1] [Anonymous], 1996, LEVEL SET METHODS
  • [2] BERNE RM, 1997, CARDIOVASCULAR PHYSL, P1
  • [3] Concomitant gradient terms in phase contrast MR: Analysis and correction
    Bernstein, MA
    Zhou, XHJ
    Polzin, JA
    King, KF
    Ganin, A
    Pelc, NJ
    Glover, GH
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (02) : 300 - 308
  • [4] ATHEROMA AND ARTERIAL WALL SHEAR - OBSERVATION, CORRELATION AND PROPOSAL OF A SHEAR DEPENDENT MASS TRANSFER MECHANISM FOR ALTHEROGENESIS
    CARO, CG
    FITZGERA.JM
    SCHROTER, RC
    [J]. PROCEEDINGS OF THE ROYAL SOCIETY SERIES B-BIOLOGICAL SCIENCES, 1971, 177 (1046): : 109 - +
  • [5] CORNHILL J, 1990, TOPOGRAPHY HUMAN AOR, P13
  • [6] ENDOTHELIAL EXPRESSION OF A MONONUCLEAR LEUKOCYTE ADHESION MOLECULE DURING ATHEROGENESIS
    CYBULSKY, MI
    GIMBRONE, MA
    [J]. SCIENCE, 1991, 251 (4995) : 788 - 791
  • [7] FLOW-MEDIATED ENDOTHELIAL MECHANOTRANSDUCTION
    DAVIES, PF
    [J]. PHYSIOLOGICAL REVIEWS, 1995, 75 (03) : 519 - 560
  • [8] DERIVATION OF SHEER RATES FROM NEAR-WALL LDA MEASUREMENTS UNDER STEADY AND PULSATILE FLOW CONDITIONS
    FATEMI, RS
    RITTGERS, SE
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1994, 116 (03): : 361 - 368
  • [9] CORRELATION BETWEEN INTIMAL THICKNESS AND FLUID SHEAR IN HUMAN ARTERIES
    FRIEDMAN, MH
    HUTCHINS, GM
    BARGERON, CB
    DETERS, OJ
    MARK, FF
    [J]. ATHEROSCLEROSIS, 1981, 39 (03) : 425 - 436
  • [10] Pulsatile flow in the human left coronary artery bifurcation: Average conditions
    He, XJ
    Ku, DN
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1996, 118 (01): : 74 - 82