Quantifying myocardial deformation throughout the cardiac cycle: A comparison of ultrasound strain rate, grey-scale m-mode and magnetic resonance imaging

被引:47
作者
Herbots, L
Maes, F
D'Hooge, J
Claus, P
Dymarkowski, S
Mertens, P
Mortelmans, L
Bijnens, B
Bogaert, J
Rademakers, FE
Sutherland, GR
机构
[1] Katholieke Univ Leuven, Univ Hosp Gasthuisberg, Dept Cardiol, B-3000 Louvain, Belgium
[2] Katholieke Univ Leuven, Univ Hosp Gasthuisberg, Dept Med Imaging Comp, Dept Elect Engn, B-3000 Louvain, Belgium
[3] Katholieke Univ Leuven, Univ Hosp Gasthuisberg, Dept Radiol, B-3000 Louvain, Belgium
[4] Katholieke Univ Leuven, Univ Hosp Gasthuisberg, Dept Nucl Med, B-3000 Louvain, Belgium
关键词
regional myocardial function; strain; echocardiography; magnetic resonance imaging;
D O I
10.1016/j.ultrasmedbio.2004.02.003
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Strain rate imaging (SRI) is a new ultrasound (US) approach to the quantification of regional myocardial deformation. It previously has been validated in vitro and in vivo against other imaging techniques. However, in all such studies, only peak strain values were compared, and the temporal evolution of the strain curve was not studied. Yet, it is the temporal evolution of the strain curves that contains the more important clinical information (e.g., asynchrony, viability, etc). Thus, the aim of this study was to compare the evolution of strain during the complete cardiac cycle as measured by US SRI, US grey-scale M-mode and magnetic resonance imaging (MRI). In 10 healthy volunteers and 20 patients with chronic ischaemic heart disease, radial deformation of the inferolateral segment of the left ventricle was measured by US SRI, US M-mode and MRI. The correspondence of the temporal characteristics of these strain curves were compared by defining an intraclass correlation coefficient (ICC). In healthy volunteers, an overall good agreement (mean ICC: 0.75 and 0.63 for systole and diastole) was found between the different methods. However, in patients with abnormal segmental deformation and low peak strain values, the agreement was less (mean ICC: 0.42 and 0.32), but remained within acceptable limits for clinical decision making. Myocardial deformation measurements using SRI correlated well with MRI and US M-mode measurements throughout the complete cardiac cycle. (E-mail: Lieven.Herbots@uz.kuleuven.ac.be) (C) 2004 World Federation for Ultrasound in Medicine Biology.
引用
收藏
页码:591 / 598
页数:8
相关论文
共 19 条
  • [1] Real-time strain rate imaging: Validation of peak compression and expansion rates by a tissue-mimicking phantom
    Belohlavek, M
    Bartleson, VB
    Zobitz, ME
    [J]. ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2001, 18 (07): : 565 - 571
  • [2] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [3] Bogaert J, 2001, AM J PHYSIOL-HEART C, V280, pH610
  • [4] Brodin LÅ, 1998, HERZ, V23, P491, DOI 10.1007/BF03043756
  • [5] SPEQLE (Software package for echocardiographic quantification., LEuven) an integrated approach to ultrasound-based cardiac deformation quantification
    Claus, P
    D'hooge, J
    Langeland, TM
    Bijnens, B
    Sutherland, GR
    [J]. COMPUTERS IN CARDIOLOGY 2002, VOL 29, 2002, 29 : 69 - 72
  • [6] Echocardiographic strain and strain-rate imaging: A new tool to study regional myocardial function
    D'hooge, J
    Bijnens, B
    Thoen, J
    Van de Werf, F
    Sutherland, GR
    Suetens, P
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (09) : 1022 - 1030
  • [7] D'hooge J, 2000, Eur J Echocardiogr, V1, P154, DOI 10.1053/euje.2000.0031
  • [8] Two-dimensional ultrasonic strain rate measurement of the human heart in vivo
    D'hooge, J
    Konofagou, E
    Jamal, F
    Heimdal, A
    Barrios, L
    Bijnens, B
    Thoen, J
    Van de Werf, F
    Sutherland, G
    Suetens, P
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2002, 49 (02) : 281 - 286
  • [9] Quantitative assessment of intrinsic regional myocardial deformation by Doppler strain rate echocardiography in humans - Validation against three-dimensional tagged magnetic resonance imaging
    Edvardsen, T
    Gerber, BL
    Garot, J
    Bluemke, DA
    Lima, JAC
    Smiseth, OA
    [J]. CIRCULATION, 2002, 106 (01) : 50 - 56
  • [10] MYOCARDIAL VELOCITY-GRADIENTS DETECTED BY DOPPLER IMAGING
    FLEMING, AD
    XIA, X
    MCDICKEN, WN
    SUTHERLAND, GR
    FENN, L
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1994, 67 (799) : 679 - 688