Microfabricated system for parallel single-cell capillary electrophoresis

被引:82
作者
Munce, NR [1 ]
Li, JZ [1 ]
Herman, PR [1 ]
Lilge, L [1 ]
机构
[1] Univ Toronto, Dept Med Biophys, Toronto, ON M5G 2M9, Canada
关键词
D O I
10.1021/ac0496906
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Performing single-cell electrophoresis separations using multiple parallel microchannels offers the possibility of both increasing throughput and eliminating cross-contamination between different separations. The instrumentation for such a system requires spatial and temporal control of both single-cell selection and lysis. To address these problems, a compact platform is presented for single-cell capillary electrophoresis in parallel microchannels that combines optical tweezers for cell selection and electromechanical lysis. Calcein-labeled acute myloid leukemia (AML) cells were selected from an on-chip reservoir and transported by optical tweezers to one of four parallel microfluidic channels. Each channel entrance was manufactured by F-2-laser ablation to form a 20- to 10-mum tapered lysis reservoir, creating an injector geometry effective in confining the cellular contents during mechanical shearing of the cell at the 10-,mum capillary entrance. The contents of individual cells were simultaneously injected into parallel channels resulting in electrophoretic separation as recorded by laser-induced fluorescence of the labeled cellular contents.
引用
收藏
页码:4983 / 4989
页数:7
相关论文
共 37 条
[1]  
Arai F, 2001, ELECTROPHORESIS, V22, P283, DOI 10.1002/1522-2683(200101)22:2<283::AID-ELPS283>3.0.CO
[2]  
2-C
[3]   Optical trapping and manipulation of neutral particles using lasers [J].
Ashkin, A .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1997, 94 (10) :4853-4860
[4]  
Chapman JAW, 1998, CYTOMETRY, V31, P67, DOI 10.1002/(SICI)1097-0320(19980101)31:1<67::AID-CYTO9>3.0.CO
[5]  
2-G
[6]   Continuous cell introduction for the analysis of individual cells by capillary electrophoresis [J].
Chen, SJ ;
Lillard, SJ .
ANALYTICAL CHEMISTRY, 2001, 73 (01) :111-118
[7]   Polyacrylamide-coated capillaries probed by atomic force microscopy:: Correlation between surface topography and electrophoretic performance [J].
Cifuentes, A ;
Díez-Masa, JC ;
Fritz, J ;
Anselmetti, D ;
Bruno, AE .
ANALYTICAL CHEMISTRY, 1998, 70 (16) :3458-3462
[8]   Microfabricated 384-lane capillary array electrophoresis bioanalyzer for ultrahigh-throughput genetic analysis [J].
Emrich, CA ;
Tian, HJ ;
Medintz, IL ;
Mathies, RA .
ANALYTICAL CHEMISTRY, 2002, 74 (19) :5076-5083
[9]   Micro-array development for cell secretion studies [J].
Feng, XJ ;
Tokranova, N ;
Xu, B ;
Chen, P ;
Gillis, K ;
Castracane, J .
MICROFLUIDICS, BIOMEMS, AND MEDICAL MICROSYSTEMS, 2003, 4982 :37-44
[10]   Electrokinetic injection techniques in microfluidic chips [J].
Fu, LM ;
Yang, RJ ;
Lee, GB ;
Liu, HH .
ANALYTICAL CHEMISTRY, 2002, 74 (19) :5084-5091