In vivo confocal microscopy through-focusing to measure corneal flap thickness after laser in situ keratomileusis

被引:50
作者
Gokmen, F [1 ]
Jester, JV [1 ]
Petroll, WM [1 ]
McCulley, JP [1 ]
Cavanagh, HD [1 ]
机构
[1] Univ Texas, SW Med Ctr, Dept Ophthalmol, Dallas, TX 75390 USA
关键词
D O I
10.1016/S0886-3350(02)01275-0
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To measure flap thickness in laser in situ keratomileusis (LASIK) patients using in vivo confocal microscopy through-focusing (CMTF) and compare measured versus intended flap thickness achieved by 2 microkeratomes, the Automated Corneal Shaper(R) (ACS) (Chiron Bausch & Lomb) and the Hansatome(R) (Bausch & Lomb). Setting: Department of Ophthalmology, University of Texas Southwestern Medical Center at Dallas, Dallas, Texas, USA. Methods: Twenty-seven eyes of 27 patients were examined by in vivo CMTF 3 to 12 months after LASIK was performed with the ACS (12 patients) or Hansatome (15 patients) microkeratome. The central cornea was scanned, and the epithelium, flap, stroma, and total corneal thickness were measured. Normalized flap thickness (NFT) was also calculated to account for changes in epithelial thickness that may have occurred postoperatively. Results: The mean posterior stromal thickness was 341.1 mum +/- 53.9 (SD) (range 233 to 431 mum) in the ACS group and 320.3 +/- 42.3 mum (range 258 to 382 mum) in the Hansatome group. The mean nonnormalized flap thickness was 132.7 +/- 12.5 mum (range 11 to 151 mum) in the ACS group and 167.4 +/- 21.4 mum (range 141 to 209 mum) in the Hansatome group. The NFT was 129.6 +/- 9.5 mum and 158.4 +/- 22.1 mum, respectively. Both microkeratomes cut significantly less than intended (P < .05); however, the ACS cut a thinner-than-intended thickness in all cases, and the Hansatome cut thicker than intended in 13% of cases. The Hansatome also showed significantly greater variability in flap thickness than the ACS (P < .05). Conclusions: A significant difference in precision was noted between the 2 microkeratomes. The findings emphasize the importance of performing thickness measurements and the usefulness of in vivo CMTF in making these determinations to ensure the safety and effectiveness of LASIK (C) 2002 ASCRS and ESCRS.
引用
收藏
页码:962 / 970
页数:9
相关论文
共 40 条
[1]  
Behrens A, 2000, J REFRACT SURG, V16, P83
[2]   Experimental evaluation of two current-generation automated microkeratomes: The Hansatome and the Supratome [J].
Behrens, A ;
Langenbucher, A ;
Kus, MM ;
Rummelt, C ;
Seitz, B .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2000, 129 (01) :59-67
[3]   An in vivo investigation of the structures responsible for corneal haze after photorefractive keratectomy and their effect on visual function [J].
Corbett, MC ;
Prydal, JI ;
Verma, S ;
Oliver, KM ;
Pande, M ;
Marshall, J .
OPHTHALMOLOGY, 1996, 103 (09) :1366-1380
[4]   THE CORRECTION OF HIGH MYOPIA USING THE EXCIMER-LASER [J].
HEITZMANN, J ;
BINDER, PS ;
KASSAR, BS ;
NORDAN, LT .
ARCHIVES OF OPHTHALMOLOGY, 1993, 111 (12) :1627-1634
[5]   Avoiding serious corneal complications of laser assisted in situ keratomileusis and photorefractive keratectomy [J].
Holland, SP ;
Srivannaboon, S ;
Reinstein, DZ .
OPHTHALMOLOGY, 2000, 107 (04) :640-652
[6]   MICROMETER-SCALE RESOLUTION IMAGING OF THE ANTERIOR EYE IN-VIVO WITH OPTICAL COHERENCE TOMOGRAPHY [J].
IZATT, JA ;
HEE, MR ;
SWANSON, EA ;
LIN, CP ;
HUANG, D ;
SCHUMAN, JS ;
PULIAFITO, CA ;
FUJIMOTO, JG .
ARCHIVES OF OPHTHALMOLOGY, 1994, 112 (12) :1584-1589
[7]  
Jacobs BJ, 1999, OPHTHALMIC SURG LAS, V30, P350
[8]  
Jester JV, 1999, METHOD ENZYMOL, V307, P230
[9]  
Kauffmann T, 1997, GER J OPHTHALMOL, V5, P508
[10]   Effect of resection velocity and suction ring on corneal flap formation in laser in situ keratomileusis [J].
Kim, YH ;
Choi, JS ;
Chun, HJ ;
Joo, CK .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (11) :1448-1455