Optimization of instrumentation precision and wavelength resolution for the performance of NIR calibrations of sucrose in a water-cellulose matrix

被引:28
作者
Greensill, CV [1 ]
Walsh, KB
机构
[1] Univ Cent Queensland, Fac Engn & Phys Syst, Rockhampton, Qld 4702, Australia
[2] Univ Cent Queensland, Primary Ind Res Ctr, Rockhampton, Qld 4702, Australia
关键词
coefficient of variation; NIR spectroscopy; reflectance; transmission; chemometrics; instrument design;
D O I
10.1366/0003702001949528
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Instrumentation for near-infrared (NIR) spectroscopic applications should be optimized for the intended application. The influence of signal precision and wavelength resolution was considered for the application of the noninvasive assessment [NIR 700-1050 nm, partial least-squares (PLS) calibration] of the sugar content of fruit, with the use of a model system of sucrose solution on cellulose. The precision (as estimated at the maximum count of the spectrum) of an MMSI Zeiss spectrometer (Carl Zeiss Pty. Ltd.) was varied by altering the number of scans averaged per spectrum, as well as the signal level. Wavelength resolution was varied between 8 and 20 nm (as estimated of the 912 nm Ar peak) by adjustment of the entrance slit of a prototype spectrometer employing a Hamamatsu S4874Q photodiode array as the detector, constructed on an optical bench. PLS calibrations were developed from interactance spectra of 0-20% w/v sucrose solution soaked filter papers, and compared on the basis of standard error of cross-validation (SECV) and coefficient of correlation-validation (R-v). The optimum measurement precision for calibration development was lower than expected at a coefficient of variation (CV) of 0.02 [signal-to-noise ratio (SNR) 5000:1]. Calibration performance was poorer at a resolution of <8 nm full width at half-maximum (FWHM) in the NIR region, but not significantly different at resolutions of between 8 and 20 nm. Further work is required to define the upper threshold of wavelength resolution. We conclude that instrumentation for the application of fruit sorting can have a relatively poor resolution, and can afford to operate at signal-to-noise levels considered low for a photodiode array detector.
引用
收藏
页码:426 / 430
页数:5
相关论文
共 11 条
  • [1] FEASIBILITY AND PERFORMANCES OF A NEW, MULTIPLEXED, FAST AND LOW-COST FIBEROPTIC NIR SPECTROMETER FOR THE ONLINE MEASUREMENT OF SUGAR IN FRUITS
    BELLON, V
    VIGNEAU, JL
    LECLERCQ, M
    [J]. APPLIED SPECTROSCOPY, 1993, 47 (07) : 1079 - 1083
  • [2] BIRTH GS, 1984, J AM SOC HORTIC SCI, V109, P1079
  • [3] An investigation into the determination of the maturity of pawpaws (Carica papaya) from NIR transmission spectra
    Greensill, CV
    Newman, DS
    [J]. JOURNAL OF NEAR INFRARED SPECTROSCOPY, 1999, 7 (02) : 109 - 116
  • [4] Robustness of NIR calibrations for soluble solids in intact melon and pineapple
    Guthrie, J
    Wedding, B
    Walsh, K
    [J]. JOURNAL OF NEAR INFRARED SPECTROSCOPY, VOL 6 1998, 1998, : 259 - 265
  • [5] KANSAKOSKI M, 1998, J NEAR INFRARED SPEC, V6, P97
  • [6] Lu J, 1998, JOURNAL OF NEAR INFRARED SPECTROSCOPY, VOL 6 1998, P77
  • [7] Validation and verification of regression in small data sets
    Martens, HA
    Dardenne, P
    [J]. CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1998, 44 (1-2) : 99 - 121
  • [8] Using near-infrared (NIR) light to estimate the soluble solids and dry matter content of kiwifruit
    Osborne, SD
    Jordan, RB
    Künnemeyer, R
    [J]. POSTHARVEST '96 - PROCEEDINGS OF THE INTERNATIONAL POSTHARVEST SCIENCE CONFERENCE, 1998, 464 : 109 - 114
  • [9] TEMMA T, 1995, P 7 INT C NEAR INFR, P638
  • [10] WANG Q, 1997, ADVANTAGES INCREASES