Mitigating SSR Using DFIG-Based Wind Generation

被引:207
作者
Fan, Lingling [1 ]
Miao, Zhixin [1 ]
机构
[1] Univ S Florida, Dept Elect Engn, Tampa, FL 33620 USA
关键词
Doubly-fed induction generator (DFIG); subsynchronous resonance (SSR) mitigation; FED INDUCTION GENERATOR; MODAL-ANALYSIS; OSCILLATIONS; CONTROLLER; TURBINES; NETWORK; STATCOM; FARMS;
D O I
10.1109/TSTE.2012.2185962
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Subsynchronous resonance (SSR) phenomenon in wind farms connected with series compensated transmission network has been researched in recent literature. Mitigating SSR using FACTS devices such as TCSC, SVC, and STATCOM has also been explored in the literature. The ability of the power converters in doubly-fed induction generator (DFIG) wind farms in mitigating SSR has rarely been investigated. In this paper, the DFIG converters will be explored for SSR mitigation. The investigation in this paper includes the design of auxiliary SSR damping controller and selection of control signals. Residue-based analysis, root locus diagrams, and time-domain simulation in Matlab/Simulink will be carried out. The major contributions of the paper are 1) investigation of the potential of wind farm converters for SSR mitigation and 2) identification of an effective control signal for SSR damping controller to simultaneously enhance both subsynchronous and supersynchronous resonance modes.
引用
收藏
页码:349 / 358
页数:10
相关论文
共 22 条
[1]  
[Anonymous], WIND FARM AGGREGATIO
[2]  
[Anonymous], P IEEE POW EN GEN M
[3]  
[Anonymous], P IEEE PES TRANSM DI
[4]   Novel STATCOM Controller for Mitigating SSR and Damping Power System Oscillations in a Series Compensated Wind Park [J].
El-Moursi, Mohamed S. ;
Bak-Jensen, Birgitte ;
Abdel-Rahman, Mansour H. .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2010, 25 (02) :429-441
[5]   Modal Analysis of a DFIG-Based Wind Farm Interfaced With a Series Compensated Network [J].
Fan, Lingling ;
Zhu, Chanxia ;
Miao, Zhixin ;
Hu, Minqiang .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2011, 26 (04) :1010-1020
[6]   Modeling of DFIG-Based Wind Farms for SSR Analysis [J].
Fan, Lingling ;
Kavasseri, Rajesh ;
Miao, Zhixin Lee ;
Zhu, Chanxia .
IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (04) :2073-2082
[7]   Selection and design of a TCSC control signal in damping power system inter-area oscillations for multiple operating conditions [J].
Fan, LL ;
Feliachi, A ;
Schoder, K .
ELECTRIC POWER SYSTEMS RESEARCH, 2002, 62 (02) :127-137
[8]   Aggregated dynamic model for wind farms with doubly fed induction generator wind turbines [J].
Fernandez, Luis M. ;
Jurado, Francisco ;
Saenz, Jose Ramon .
RENEWABLE ENERGY, 2008, 33 (01) :129-140
[9]   A power system stabilizer for DFIG-based wind generation [J].
Hughes, FM ;
Anaya-Lara, O ;
Jenkins, N ;
Strbac, G .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2006, 21 (02) :763-772
[10]  
IEEE Committee Report, 1977, IEEE Trans Power Appl Syst, V96, P1565