The inlet temperature as a boundary condition for multiple-skin facade modelling

被引:53
作者
Saelens, D [1 ]
Roels, S [1 ]
Hens, H [1 ]
机构
[1] Katholieke Univ Leuven, Dept Civil Engn, Lab Bldg Phys, B-3001 Heverlee, Belgium
关键词
multiple-skin facade; building envelope; advanced envelope; energy simulation; fenestration;
D O I
10.1016/j.enbuild.2004.01.005
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper draws the attention to the importance of a correct modelling of the inlet temperature of naturally and mechanically ventilated multiple-skin facades. Measurements demonstrate that the assumption of an inlet temperature equal to the interior or exterior air temperature is usually not valid. A sensitivity study illustrates the significance of the inlet temperature as a boundary condition for numerical multiple-skin facade models. Finally, the inlet temperature model and multiple-skin facade model are used in a whole building energy simulation to indicate the importance of a correct inlet temperature on the energy performance. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:825 / 835
页数:11
相关论文
共 19 条
[1]  
Compagno A., 1995, INTELLIGENT GLASS FA
[2]   SOLAR ABSORPTION BY EACH ELEMENT IN AN ABSORBER-COVERGLASS ARRAY [J].
EDWARDS, DK .
SOLAR ENERGY, 1977, 19 (04) :401-402
[3]  
Haddad KH., 1998, ASHRAE T, V104, P1261
[4]  
HENSEN JLM, 2002, MODELING SIMULATION, V108
[5]  
JANSSENS B, 2003, THESIS ROYAL MILITAR
[6]  
LANG W, 1998, DETAIL, V7, P1125
[7]  
Liddament M. W., 1996, GUIDE ENERGY EFFICIE
[8]   Empirical validation of building energy simulation programs [J].
Lomas, KJ ;
Eppel, H ;
Martin, CJ ;
Bloomfield, DP .
ENERGY AND BUILDINGS, 1997, 26 (03) :253-275
[9]  
Manz H, 2003, RESEARCH IN BUILDING PHYSICS, P519
[10]  
MITALAS GP, 1978, ASHRAE T, V84, P667