Comparison and Analysis of Single-Phase Transformerless Grid-Connected PV Inverters

被引:237
作者
Freddy, Tan Kheng Suan [1 ,2 ]
Rahim, Nasrudin A. [1 ]
Hew, Wooi-Ping [1 ]
Che, Hang Seng [1 ]
机构
[1] Univ Malaya, UMPEDAC, Kuala Lumpur 59990, Malaysia
[2] Univ Malaya, Fac Engn, Kuala Lumpur 50603, Malaysia
关键词
Common-mode voltage (CMV); leakage current; photovoltaic (PV) system; transformerless; RELIABILITY; TOPOLOGIES;
D O I
10.1109/TPEL.2013.2294953
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Leakage current minimization is one of the most important considerations in transformerless photovoltaic (PV) inverters. In the past, various transformerless PV inverter topologies have been introduced, with leakage current minimized by the means of galvanic isolation and common-mode voltage (CMV) clamping. The galvanic isolation can be achieved via dc-decoupling or ac-decoupling, for isolation on the dc- or ac-side of the inverter, respectively. It has been shown that the latter provides lower losses due to the reduced switch count in conduction path. Nevertheless, leakage current cannot be simply eliminated by galvanic isolation and modulation techniques, due to the presence of switches' junction capacitances and resonant circuit effects. Hence, CMV clamping is used in some topologies to completely eliminate the leakage current. In this paper, several recently proposed transformerless PV inverters with different galvanic isolation methods and CMV clamping technique are analyzed and compared. A simple modified H-bridge zero-voltage state rectifier is also proposed, to combine the benefits of the low-loss ac-decoupling method and the complete leakage current elimination of the CMV clamping method. The performances of different topologies, in terms of CMV, leakage current, total harmonic distortion, losses and efficiencies are compared. The analyses are done theoretically and via simulation studies, and further validated with experimental results. This paper is helpful for the researchers to choose the appropriate topology for transformerless PV applications and to provide the design principles in terms of common-mode behavior and efficiency.
引用
收藏
页码:5358 / 5369
页数:12
相关论文
共 34 条
[1]   Single-Phase Single-Stage Transformer less Grid-Connected PV System [J].
Alajmi, Bader N. ;
Ahmed, Khaled H. ;
Adam, Grain Philip ;
Williams, Barry W. .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2013, 28 (06) :2664-2676
[2]  
[Anonymous], 2007, PSIM USERS GUIDE
[3]   Highly Efficient Single-Phase Transformerless Inverters for Grid-Connected Photovoltaic Systems [J].
Araujo, Samuel Vasconcelos ;
Zacharias, Peter ;
Mallwitz, Regine .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2010, 57 (09) :3118-3128
[4]  
Automatic Disconnection Device between a Generator and the Public Low-Voltage Grid, 2005, 012611 DIN VDE
[5]  
Azevedo GMS, 2009, PROC IEEE INT SYMP, P544
[6]  
Barater D, 2012, IEEE IND ELEC, P5756, DOI 10.1109/IECON.2012.6389044
[7]   Modulation for Three-Phase Transformerless Z-Source Inverter to Reduce Leakage Currents in Photovoltaic Systems [J].
Bradaschia, Fabricio ;
Cavalcanti, Marcelo C. ;
Ferraz, Pedro E. P. ;
Neves, Francisco A. S. ;
dos Santos, Euzeli C., Jr. ;
da Silva, Joao H. G. M. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2011, 58 (12) :5385-5395
[8]  
Calais M, 2002, IEEE POWER ELECTRON, P1995, DOI 10.1109/PSEC.2002.1023107
[9]   Eliminating Leakage Currents in Neutral Point Clamped Inverters for Photovoltaic Systems [J].
Cavalcanti, Marcelo C. ;
Farias, Alexandre M. ;
Oliveira, Kleber C. ;
Neves, Francisco A. S. ;
Afonso, Joao L. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2012, 59 (01) :435-443
[10]   Modulation Techniques to Eliminate Leakage Currents in Transformerless Three-Phase Photovoltaic Systems [J].
Cavalcanti, Marcelo C. ;
de Oliveira, Kleber C. ;
de Farias, Alexandre M. ;
Neves, Francisco A. S. ;
Azevedo, Gustavo M. S. ;
Camboim, Felipe C. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2010, 57 (04) :1360-1368