Can we rely on arterial line sampling in performing activated plasma thromboplastin time after cardiac surgery?

被引:12
作者
Alzetani, A [1 ]
Vohra, HA [1 ]
Patel, RL [1 ]
机构
[1] Walsgrave Gen Hosp, Dept Cardiothorac Surg, Univ Hosp Coventry & Warwickshire NHS Trust, Coventry, W Midlands, England
关键词
blood coagulation tests; partial thromboplastin time; thromboelastography; catheters; indwelling; arterial;
D O I
10.1017/S026502150400506X
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background and objective: Arterial catheters are routinely used to sample blood for clotting studies in most cardiothoracic intensive care units. The clotting profile in surgical bleeding after cardiac surgery influences further management. Aspiration and discard of a certain amount of blood from the line, prior to sampling, are assumed to clear heparin contamination. We have investigated this assumption through analysis of the clotting profile by simultaneous arterial line and peripheral venous samples. Methods: The morning following cardiac surgery, simultaneous arterial line and peripheral venous blood samples were taken for activated plasma thromboplastin time (APTT) ratio and international normalized ratio (INR) in 49 randomly selected patients. Also, a thromboelastogram analysis (TEG) (n=7) was made. A survey of 22 UK cardiothoracic intensive care units was carried out to determine the practice for the withdrawal of blood for clotting studies. Results: The median arterial APTT ratio value was 1.32+/-0.52 as compared to the median peripheral APTT ratio value which was 1.1+/-0.24 (P<0.001). INR values were statistically similar by both routes. Heparin contamination was confirmed by TEG which revealed that the R-value for arterial catheter blood samples without heparinase in the cup was higher (406.00 +/- 64.44 s) compared with the value for arterial samples with heparinase in the cup (318.28 +/- 47.26s, P<0.05). The survey of 22 UK cardiothoracic intensive care units showed that heparinized arterial lines were by far the commonest ports used for blood withdrawal for the measurement of APTT ratio results. Conclusions: Samples withdrawn from heparinized arterial lines cannot be relied upon for APTT ratio results.
引用
收藏
页码:384 / 388
页数:5
相关论文
共 8 条
[1]   EFFICACY OF 1.4 PERCENT SODIUM-CITRATE IN MAINTAINING ARTERIAL CATHETER PATENCY IN PATIENTS IN A MEDICAL ICU [J].
BRANSON, PK ;
MCCOY, RA ;
PHILLIPS, BA ;
CLIFTON, GD .
CHEST, 1993, 103 (03) :882-885
[2]  
Gamby A, 1995, Intensive Crit Care Nurs, V11, P148, DOI 10.1016/S0964-3397(95)80644-X
[3]   Are coagulation studies on blood sampled from arterial lines valid? [J].
Heap, MJ ;
Ridley, SA ;
Hodson, K ;
Martos, FJ .
ANAESTHESIA, 1997, 52 (07) :640-645
[4]  
Konopad E, 1992, Am J Crit Care, V1, P94
[5]  
KULKARNI M, 1994, CAN J SURG, V37, P37
[6]  
Laxson C J, 1994, Am J Crit Care, V3, P16
[7]   INTRAARTERIAL BLOOD-SAMPLING FOR CLOTTING STUDIES - EFFECTS OF HEPARIN CONTAMINATION [J].
LEW, JKL ;
HUTCHINSON, R ;
LIN, ES .
ANAESTHESIA, 1991, 46 (09) :719-721
[8]  
Templin K, 1993, Am J Crit Care, V2, P88