A comparison of subdermal wire electrodes with collodion-applied disk electrodes in long-term EEG recordings in ICU

被引:34
作者
Young, G. Bryan
Ives, John R.
Chapman, Martin G.
Mirsattari, Seyed M.
机构
[1] Univ Western Ontario, Univ Hosp, Dept Clin Neurol Sci, London, ON N6A 5A5, Canada
[2] Univ Toronto, Toronto, ON, Canada
关键词
EEG; electrodes; subdermal wire; disk; artifact; cEEG; LTM;
D O I
10.1016/j.clinph.2006.02.006
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: To compare long-term electroencephalographic (EEG) recordings of standard collodion-applied scalp disk electrodes (SDEs) with newly developed subdermal wire electrodes (SWEs) in comatose intensive care unit (ICU) patients. Methods: Ten comatose ICU patients had simultaneous recordings from 8 active SDEs and 8 active SVV'E for > 24 h. The timing and number of 60 Hz and other electrode artifacts were compared for each set of electrodes by an EEGer who read the recordings in a blinded manner. Results: Sixty Hertz artifact was seen in 16 of 80 SDE and one of 80 SWEs within the first 6 h (P = 0.0002). Large, persistent artifacts occurred in 30/80 SDE and 8 of 80 SWE (P=0.0001). Motion artifact with chest physiotherapy was more common in SWEs. Conclusions: SWE are less susceptible to artifacts and are more suitable for the long-term EEG monitoring in ICU. Significance: This is the first controlled study that demonstrates the superiority of SWEs compared to SDEs in an ICU population. (c) 2006 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1376 / 1379
页数:4
相关论文
共 14 条
[1]   Detection of electrographic seizures with continuous EEG monitoring in critically ill patients [J].
Claassen, J ;
Mayer, SA ;
Kowalski, RG ;
Emerson, RG ;
Hirsch, LJ .
NEUROLOGY, 2004, 62 (10) :1743-1748
[2]  
COOPER R, 1974, EEG TECHNOLOGY, P98
[3]   New chronic EEG electrode for critical/intensive care unit monitoring [J].
Ives, JR .
JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 2005, 22 (02) :119-123
[4]   UPDATE - CHRONIC SPHENOIDAL ELECTRODES [J].
IVES, JR ;
GLOOR, P .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1978, 44 (06) :789-790
[5]   NEW SPHENOIDAL ELECTRODE ASSEMBLY TO PERMIT LONG-TERM MONITORING OF PATIENTS ICTAL OR INTERICTAL EEG [J].
IVES, JR ;
GLOOR, P .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1977, 42 (04) :575-580
[6]  
Lothman E.W., 1993, AM J EEG TECHNOL, V33, P93
[7]   Real-time display of artifact-free electroencephalography during functional magnetic resonance imaging and magnetic resonance spectroscopy in an animal model of epilepsy [J].
Mirsattari, SM ;
Ives, JR ;
Bihari, F ;
Leung, LS ;
Menon, RS ;
Bartha, R .
MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (02) :456-464
[8]   Continuous EEG monitoring for the detection of seizures in traumatic brain injury, infarction, and intracerebral hemorrhage: "To detect and protect" [J].
Vespa, P .
JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 2005, 22 (02) :99-106
[9]   Early detection of vasospasm after acute subarachnoid hemorrhage using continuous EEG ICU monitoring [J].
Vespa, PM ;
Nuwer, MR ;
Juhász, C ;
Alexander, M ;
Nenov, V ;
Martin, N ;
Becker, DP .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1997, 103 (06) :607-615
[10]   Early and persistent impaired percent alpha variability on continuous electroencephalography monitoring as predictive of poor outcome after traumatic brain injury [J].
Vespa, PM ;
Boscardin, WJ ;
Hovda, DA ;
McArthur, DL ;
Nuwer, MR ;
Martin, NA ;
Nenov, V ;
Glenn, TC ;
Bergsneider, M ;
Kelly, DF ;
Becker, DP .
JOURNAL OF NEUROSURGERY, 2002, 97 (01) :84-92