Mapping of enzyme activity by detection of enzymatic products during AFM imaging with integrated SECM-AFM probes

被引:64
作者
Kranz, C [1 ]
Kueng, A
Lugstein, A
Bertagnolli, E
Mizaikoff, B
机构
[1] Georgia Inst Technol, Sch Chem & Biochem, Atlanta, GA 30332 USA
[2] Vienna Univ Technol, Solid State Elect Inst, A-1040 Vienna, Austria
关键词
atomic force microscopy; scanning electrochemical microscopy; combined SECM-AFM; integrated SECM-AFM probes; enzyme activity; self-assembled monolayers; thin films;
D O I
10.1016/j.ultramic.2003.10.004
中图分类号
TH742 [显微镜];
学科分类号
摘要
With the integration of submicro- and nanoelectrodes into atomic force microscopy (AFM) probes using microfabrication techniques, an elegant approach combining scanning electrochemical microscopy (SECM) with AFM has recently been introduced. Simultaneous contact mode imaging of a micropatterned sample with immobilized enzyme spots and imaging of enzyme activity is shown. In contrast to force spectroscopy the conversion of an enzymatic byproduct is directly detected during AFM imaging and correlated to the activity of the enzyme. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:127 / 134
页数:8
相关论文
共 44 条
[1]  
AKALAH A, 1981, FUNCTIONALIZED POLYM
[2]   CHEMICAL IMAGING OF SURFACES WITH THE SCANNING ELECTROCHEMICAL MICROSCOPE [J].
BARD, AJ ;
FAN, FRF ;
PIERCE, DT ;
UNWIN, PR ;
WIPF, DO ;
ZHOU, FM .
SCIENCE, 1991, 254 (5028) :68-74
[3]  
BARD AJ, 1994, ELECTROANALYTICAL CH, V18, P268
[4]  
BARTLETT PN, 1993, J ELECTROANAL CHEM, V362, P1
[5]   Adsorption and bioactivity of protein A on silicon surfaces studied by AFM and XPS [J].
Coen, MC ;
Lehmann, R ;
Gröning, P ;
Bielmann, M ;
Galli, C ;
Schlapbach, L .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2001, 233 (02) :180-189
[6]   Nanometer-scale surface properties of mixed phospholipid monolayers and bilayers [J].
Dufrene, YF ;
Barger, WR ;
Green, JBD ;
Lee, GU .
LANGMUIR, 1997, 13 (18) :4779-4784
[7]  
EROKHIN V, 1991, PROG COLL POL SCI S, V85, P47, DOI 10.1007/BFb0114808
[8]  
Gill I., 2000, STEREOSELECTIVE BIOC, P741
[9]   Parameters important in fabricating enzyme electrodes using self-assembled monolayers of alkanethiols [J].
Gooding, JJ ;
Erokhin, P ;
Losic, D ;
Yang, WR ;
Policarpio, V ;
Liu, JQ ;
Ho, FM ;
Situmorang, M ;
Hibbert, DB ;
Shapter, JG .
ANALYTICAL SCIENCES, 2001, 17 (01) :3-9
[10]   Atomic force microscope imaging of phospholipid bilayer degradation by phospholipase A2 [J].
Grandbois, M ;
Clausen-Schaumann, H ;
Gaub, H .
BIOPHYSICAL JOURNAL, 1998, 74 (05) :2398-2404