Bromide/bromate speciation by NTI-IDMS and ICP-MS coupled with ion exchange chromatography

被引:48
作者
Diemer, J [1 ]
Heumann, KG [1 ]
机构
[1] UNIV MAINZ,INST INORGAN & ANALYT CHEM,D-55099 MAINZ,GERMANY
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 1997年 / 357卷 / 01期
关键词
D O I
10.1007/s002160050114
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two different mass spectrometric methods, negative thermal ionization isotope dilution mass spectrometry (NTI-IDMS) and inductively coupled plasma mass spectrometry (ICP-MS), off-line and on-line coupled with anion exchange chromatography, have been developed for simultaneous bromide and bromate determinations in water samples. The detection limits of these methods are in the range of 0.03-0.09 mu g/L using a 50 mL sample. The results are independent of the content of other anions, which could be demonstrated by the analyses of six mineral waters containing chloride and sulfate of up to 160 mg/L and 1500 mg/L, respectively. Bromide has been analyzed by the NTI-IDMS method in the range of 10-500 mu g/L and bromate in the range of 1-50 mu g/L with relative standard deviations of 0.3-1.2% and 0.4-6%. Quantification for the ICP-MS method was carried out by the standard addition technique, which resulted in relative standard deviations of 5.5% for bromide at the 500 mu g/L level and of 13% for bromate at the level of about 3 mu g/L. These results are compared with those described in the literature for ion chromatographic (IC) and other methods and those obtained in this work by IC using UV detection, which allows high concentrations of chloride in the bromate fraction. The detection limits of this IC method are 6 mu g/L for bromide and 30 mu g/L for bromate. NTI-IDMS and ICP-MS therefore fit the recommendations of the European Union (detection limit < 2.5 mu g/L; precision and accuracy better than 25% at the 10 mu g/L level) for methods analyzing the carcinogenic bromate much better than IC and other methods applied up to now. As a definitive but time consuming method, NTI-IDMS is preferably applicable as a calibration technique, whereas ICP-MS, with relatively short analysis times, due to on-line coupling with chromatography, can be used as a sensitive and powerful routine method for trace bromide and bromate species in water samples.
引用
收藏
页码:74 / 79
页数:6
相关论文
共 21 条
[1]  
Commission of the European Communities, 1994, PROP COUNC DIR QUAL
[2]   DETERMINATION OF LEAD AND OTHER TRACE-ELEMENT SPECIES IN BLOOD BY SIZE EXCLUSION CHROMATOGRAPHY AND INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
GERCKEN, B ;
BARNES, RM .
ANALYTICAL CHEMISTRY, 1991, 63 (03) :283-287
[3]  
GERZ R, 1993, THESIS FACHHOCHSCHUL
[4]   A FLOW-INJECTION, NON-ION CHROMATOGRAPHIC METHOD FOR MEASURING LOW-LEVEL BROMATE ION IN OZONE TREATED WATERS [J].
GORDON, G ;
BUBNIS, B ;
SWEETIN, D ;
KUO, CY .
OZONE-SCIENCE & ENGINEERING, 1994, 16 (01) :79-87
[5]  
GREENWOOD NN, 1988, CHEM ELEMENTE, P1027
[6]   ANALYSIS OF OXYHALIDE DISINFECTION BY-PRODUCTS AND OTHER ANIONS OF INTEREST IN DRINKING-WATER BY ION CHROMATOGRAPHY [J].
HAUTMAN, DP ;
BOLYARD, M .
JOURNAL OF CHROMATOGRAPHY, 1992, 602 (1-2) :65-74
[7]   APPLICATION OF AN ECONOMICAL AND SMALL THERMAL IONIZATION MASS-SPECTROMETER FOR ACCURATE ANION TRACE ANALYSES [J].
HEUMANN, KG ;
SCHINDLMEIER, W ;
ZEININGER, H ;
SCHMIDT, M .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1985, 320 (05) :457-462
[8]   ISOTOPE-DILUTION MASS-SPECTROMETRY (IDMS) OF THE ELEMENTS [J].
HEUMANN, KG .
MASS SPECTROMETRY REVIEWS, 1992, 11 (01) :41-67
[9]   SIMULTANEOUS DETERMINATION OF CL-, BR- AND I- IN WATER SAMPLES BY ISOTOPE-DILUTION MASS-SPECTROMETRY [J].
HEUMANN, KG ;
SEEWALD, H .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1985, 320 (05) :493-497
[10]   ELEMENTAL SPECIATION WITH LIQUID-CHROMATOGRAPHY INDUCTIVELY-COUPLED PLASMA ISOTOPE-DILUTION MASS-SPECTROMETRY [J].
HEUMANN, KG ;
ROTTMANN, L ;
VOGL, J .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (12) :1351-1355