Magnetoencephalography-directed surgery in patients with neocortical epilepsy

被引:76
作者
Mamelak, AN
Lopez, N
Akhtari, M
Sutherling, WW
机构
[1] Huntington Med Res Inst, Pasadena, CA USA
[2] Huntington Mem Hosp, Epilepsy & Brain Mapping Program, Pasadena, CA USA
[3] City Hope Natl Med Ctr, Duarte, CA 91010 USA
关键词
magnetoencephalography; magnetic source imaging; electrocorticography; epilepsy; cortical mapping;
D O I
10.3171/jns.2002.97.4.0865
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. Magnetoencephalography (MEG) and magnetic source (MS) imaging are techniques that have been increasingly used for preoperative localization of epileptic foci and areas of eloquent cortex. The use of MEG examinations must be carefully balanced against the high cost and technological investments required to perform these studies, particularly when less expensive alternative localization methods are available. To help elucidate the value of MEG, the authors have critically reviewed their experience with whole-head MEG in the case management of patients undergoing epilepsy surgery. Methods. The authors identified 1-3 patients with suspected focal epilepsy who underwent whole-head MEG and MS imaging at Huntington Memorial Hospital and, subsequently, underwent invasive intracranial electrode monitoring and electrocorticography (ECoG) to localize the zone of seizure origin for surgical resection. The results of the MS imaging were retrospectively stratified into three groups by the number of interictal spikes recorded during a 4-hour recording session: Class I (no spikes), Class II (less than or equal to five spikes), and Class III (greater than or equal to six spikes). Class III was further subdivided according to the clustering density of the interictal spikes: Class IIIA represents a mean distance between interictal spikes of 4 mm or greater (that is, diffusely clustered) and Class IIIB represents a mean distance between interictal spikes of less than 4 mm (that is, densely clustered). The authors analyzed these groups to determine to what extent the results of MS imaging correlated with the ECoG-determined zone of seizure origin. In addition, they assessed whether the MS imaging study provided critical localization data and correlated with surgical outcome following resection. A statistical analysis of these correlations was also performed. Of the 40 patients studied, 23 underwent invasive monitoring, including 13 with neocortical epilepsy, four with mesial temporal lobe epilepsy, and six with suspected neocortical epilepsy that could not be clearly localized by ECoG. Depth electrodes were used in nine cases, subdural grids in nine cases, depth electrodes followed by subdural grids and strips in four cases, and intraoperative ECoG in one case. Electrocorticography was able to localize the zone of seizure origin in 16 (70%) of 23 cases. In 11 (69%) of the 16 cases in which ECoG was able to localize the zone of seizure origin, the interictal spikes on the MS images were classified as Class IIIB (densely clustered) and regionally correlated to the MS imaging-determined localization in all cases (that is, the same lobe), In contrast, no Class IIIB cases were identified when ECoG was unable to localize the zone of seizure origin. This difference showed a trend toward, but did not achieve, statistical significance (p < 0.23), presumably because of the relatively small number of cases available for analysis. In three cases (all Class IIIB), MS imaging was used to guide invasive electrodes to locations that otherwise Would not have been targeted and provided unique localization data, not evident from other imaging modalities, that strongly influenced the surgical management of the patient. The classification of findings on MS images into subgroups and subsequent statistical analysis generated a model that predicted that Class IIIB MS imaging data are likely to provide reliable information to guide surgical placement of electrodes, but all other data groups do not provide localization information that is reliable enough to guide surgical decision making. Conclusions. Magnetic source imaging can provide unique localization information that is not available when other noninvasive methods are used. Magnetic source imaging appears most useful for cases of neocortical epilepsy. In particular, when an MS imaging study revealed six or more interictal spikes that were densely clustered in a single anatomical location, the MS image was highly correlated with the zone of seizure origin identified by ECoG. In these cases the MS imaging data may be useful to guide placement of intracranial electrodes.
引用
收藏
页码:865 / 873
页数:9
相关论文
共 37 条
[21]  
2-C
[22]   Dipole source localization of ictal epileptiform activity [J].
Mine, S ;
Yamaura, A ;
Iwasa, H ;
Nakajima, Y ;
Shibata, T ;
Itoh, T .
NEUROREPORT, 1998, 9 (18) :4007-4013
[23]   Recursive MUSIC: A framework for EEG and MEG source localization [J].
Mosher, JC ;
Leahy, RM .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1998, 45 (11) :1342-1354
[24]   EEG source localization and imaging using multiple signal classification approaches [J].
Mosher, JC ;
Baillet, S ;
Leahy, RM .
JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 1999, 16 (03) :225-238
[25]   COMPARISONS OF MEG, EEG, AND ECOG SOURCE LOCALIZATION IN NEOCORTICAL PARTIAL EPILEPSY IN HUMANS [J].
NAKASATO, N ;
LEVESQUE, MF ;
BARTH, DS ;
BAUMGARTNER, C ;
ROGERS, RL ;
SUTHERLING, WW .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1994, 91 (03) :171-178
[26]   Subtraction peri-ictal SPECT is predictive of extratemporal epilepsy surgery outcome [J].
O'Brien, TJ ;
So, EL ;
Mullan, BP ;
Cascino, GD ;
Hauser, MF ;
Brinkmann, BH ;
Sharbrough, FW ;
Meyer, FB .
NEUROLOGY, 2000, 55 (11) :1668-1677
[27]   Subtraction ictal SPECT co-registered to MRI improves clinical usefulness of SPECT in localizing the surgical seizure focus [J].
O'Brien, TJ ;
So, EL ;
Mullan, BP ;
Hauser, MF ;
Brinkmann, BH ;
Bohnen, NI ;
Hanson, D ;
Cascino, GD ;
Jack, CR ;
Sharbrough, FW .
NEUROLOGY, 1998, 50 (02) :445-454
[28]   Confirmation of two magnetoencephalographic epileptic foci by invasive monitoring from subdural electrodes in an adolescent with right frontocentral epilepsy [J].
Otsubo, H ;
Sharma, R ;
Elliott, I ;
Holowka, S ;
Rutka, JT ;
Snead, OC .
EPILEPSIA, 1999, 40 (05) :608-613
[29]  
Rezai AR, 1997, ADV STER F, V12, P85
[30]   Dipole localization in patients with epilepsy using the realistically shaped head model [J].
Roth, BJ ;
Ko, D ;
vonAlbertiniCarletti, IR ;
Scaffidi, D ;
Sato, S .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1997, 102 (03) :159-166