Comparison of acute effects on right ventricular haemodynamics of surgical versus interventional closure of atrial septal defects

被引:23
作者
Berger, F
Jin, Z
Ishihashi, K
Vogel, B
Ewert, P
Alexi-Meshkishvili, V
Weng, Y
Lange, PE
机构
[1] Deutsch Herzzentrum Berlin, Dept Congenital Heart Dis, D-13353 Berlin, Germany
[2] Deutsch Herzzentrum Berlin, Dept Cardiac Surg, D-13353 Berlin, Germany
关键词
atrial septal defect; echocardiography; right ventricular function;
D O I
10.1017/S1047951100005394
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: We compared the acute effects on right ventricular haemodynamics of surgical versus transcatheter closure of medium-sized atrial septal defects. Method's: We studied 47 consecutive patients with a defect in the oval fossa and a ratio of pulmonary to systemic flows between 1.5: 1 and 2: 1. They were divided into two groups according to whether the defects were closed by surgery, performed in 23 patients, or by interventional catheterization, achieved in 24 patients. By means of transthoracic cross-sectional echocardiography, we measured right ventricular end-diastolic and endsystolic volumes and calculated ejection fractions. These calculations were performed before, and between 1 and 7 days after closure of the defect. Results: Before closure of the defect, all patients had an enlarged right ventricle with normal function. After closure by either method, there was no difference in the rate of normalization of end-diastolic volume, but endsystolic volume remained enlarged. Thus, the calculated ejection fraction was lower than before closure. Conclusions: There was no difference in right ventricular volumes or function early after closure of atrial septal defects, irrespective of whether this was achieved surgically or via transcatheter closure.
引用
收藏
页码:484 / 487
页数:4
相关论文
共 15 条
  • [1] Initial clinical results with the Amplatzer septal occluder - a self-centering double-disc device for the occlusion of atrial septal defects
    Berger, F
    Ewert, P
    Stiller, B
    Dahnert, I
    Krings, G
    Vogel, M
    Lange, PE
    [J]. ZEITSCHRIFT FUR KARDIOLOGIE, 1998, 87 (03): : 185 - 190
  • [2] BERGER F, 1995, CARDIOL YOUNG S1, V5, P1
  • [3] ECHOCARDIOGRAPHIC FOLLOW-UP OF ATRIAL SEPTAL-DEFECT AFTER CATHETER CLOSURE BY DOUBLE-UMBRELLA DEVICE
    BOUTIN, C
    MUSEWE, NN
    SMALLHORN, JF
    DYCK, JD
    KOBAYASHI, T
    BENSON, LN
    [J]. CIRCULATION, 1993, 88 (02) : 621 - 627
  • [4] EXPERIMENTAL ATRIAL SEPTAL-DEFECT CLOSURE WITH A NEW, TRANSCATHETER, SELF-CENTERING DEVICE
    DAS, GS
    VOSS, G
    JARVIS, G
    WYCHE, K
    GUNTHER, R
    WILSON, RF
    [J]. CIRCULATION, 1993, 88 (04) : 1754 - 1764
  • [5] Should atrial septal defects in adults be closed?
    Gatzoulis, MA
    Redington, AN
    Somerville, J
    Shore, DF
    [J]. ANNALS OF THORACIC SURGERY, 1996, 61 (02) : 657 - 659
  • [6] Transcatheter closure of secundum atrial septal defects with the atrial septal defect occlusion system (ASDOS): Initial experience in children
    Hausdorf, G
    Schneider, M
    Franzbach, B
    Kampmann, C
    Kargus, K
    Goeldner, B
    [J]. HEART, 1996, 75 (01) : 83 - 88
  • [7] HUYSMANS HA, 1989, Z KARDIOL, V78, P43
  • [8] Cross-sectional echocardiographic determination of right ventricular volume and myocardial mass in children. Normal values and values in children with interatrial communication
    Jin, Z
    Briedigkeit, W
    Gamillscheg, A
    Berger, F
    Skinner, JR
    Golshahi, F
    Uhlemann, F
    Lange, PE
    [J]. CARDIOLOGY IN THE YOUNG, 1997, 7 (03) : 302 - 309
  • [9] SECUNDUM ATRIAL SEPTAL-DEFECT - NONOPERATIVE CLOSURE DURING CARDIAC-CATHETERIZATION
    KING, TD
    THOMPSON, SL
    STEINER, C
    MILLS, NL
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1976, 235 (23): : 2506 - 2509
  • [10] Masura J, 1997, CATHETER CARDIO DIAG, V42, P388, DOI 10.1002/(SICI)1097-0304(199712)42:4<388::AID-CCD7>3.0.CO