Arterial elastance and heart-arterial coupling in aortic regurgitation are determined by aortic leak severity

被引:7
作者
Segers, P
Morimont, P
Kolh, P
Stergiopulos, N
Westerhof, N
Verdonck, P
机构
[1] State Univ Ghent, Inst Biomed Technol, Hydraul Lab, B-9000 Ghent, Belgium
[2] Univ Liege, Ctr Hosp Univ, Liege, Belgium
[3] EPFL, Biomed Engn Lab, CH-1015 Lausanne, Switzerland
[4] Vrije Univ Amsterdam, ICaR VU, Physiol Lab, Amsterdam, Netherlands
关键词
D O I
10.1067/mhj.2002.124398
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background In aortic valve regurgitation (AR), aortic leak severity modulates left ventricle (LV) arterial system interaction. The aim of this study was to assess (1) how arterial elastance (E-a), calculated as the ratio of LV end-systolic pressure and stroke volume, relates to arterial properties and leak severity and (2) the validity of E-a/E-max (with E-max the slope of the-end-systolic pressure-volume relation) as a heart-arterial coupling parameter in AR. Methods and Results Our work is based on human data obtained from a study on vascular adaptation in chronic AR. These data allowed us to assess the parameters of a computer model of heart-arterial interaction. In particular, total peripheral resistance (R) and aortic leak severity-expressed as leak resistance (R-L,R-ao)-were quantified for different patient subgroups (group I/IIa/IIb: E-max = 2.15/0.62/0.47 mm Hg/mL; E-a = 1.24/0.66/0.90 mm Hg/mL; R = 1.9/0.6/0.85 mm Hg-s/mL, R-L,R-ao = 0.35/0.05/0.20 mm Hg-s/mL). A parameter study demonstrated that R-L,R-ao was the main determinant of E-a. With all other parameters constant, valve repair would increase E-a to 2.81, 1.08, and 1.54 mm Hg/mL in groups I,IIa, and IIb, respectively. For a given E-a/E-max, LV pump efficiency (estimated as the ratio of stroke work and LV systolic pressure-volume area) was lower than the theoretical predicted value, except for the simulations with intact aortic valve. Conclusions In AR(a) E-a is determined by aortic leak severity rather than by arterial system properties. Using E-a/E-max as a coupling parameter in general or as a mechanico-energetic regulatory parameter in particular is questionable.
引用
收藏
页码:568 / 576
页数:9
相关论文
共 26 条
[1]   Ventriculoarterial coupling and left ventricular efficiency in heart transplant recipients [J].
Arnoult, F ;
Loiseau, A ;
Aptecar, E ;
Loisance, D ;
Nitenberg, A .
TRANSPLANTATION, 1997, 64 (04) :617-626
[2]   VENTRICULOARTERIAL COUPLING IN NORMAL AND FAILING HEART IN HUMANS [J].
ASANOI, H ;
SASAYAMA, S ;
KAMEYAMA, T .
CIRCULATION RESEARCH, 1989, 65 (02) :483-493
[3]   VENTRICULAR EFFICIENCY PREDICTED BY AN ANALYTICAL MODEL [J].
BURKHOFF, D ;
SAGAWA, K .
AMERICAN JOURNAL OF PHYSIOLOGY, 1986, 250 (06) :1021-1027
[4]   Coupled systolic-ventricular and vascular stiffening with age implications for pressure regulation and cardiac reserve in the elderly [J].
Chen, CH ;
Nakayama, M ;
Nevo, E ;
Fetics, BJ ;
Maughan, WL ;
Kass, DA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (05) :1221-1227
[5]   VENTRICULAR STROKE WORK AND EFFICIENCY BOTH REMAIN NEARLY OPTIMAL DESPITE ALTERED VASCULAR LOADING [J].
DETOMBE, PP ;
JONES, S ;
BURKHOFF, D ;
HUNTER, WC ;
KASS, DA .
AMERICAN JOURNAL OF PHYSIOLOGY, 1993, 264 (06) :H1817-H1824
[6]   Impact of vascular adaptation to chronic aortic regurgitation on left ventricular performance [J].
Devlin, WH ;
Petrusha, J ;
Briesmiester, K ;
Montgomery, D ;
Starling, MR .
CIRCULATION, 1999, 99 (08) :1027-1033
[7]   MATCHING BETWEEN VENTRICLE AND ARTERIAL LOAD - AN EVOLUTIONARY PROCESS [J].
ELZINGA, G ;
WESTERHOF, N .
CIRCULATION RESEARCH, 1991, 68 (06) :1495-1500
[8]  
Haessler R, 1992, J Cardiothorac Vasc Anesth, V6, P173, DOI 10.1016/1053-0770(92)90193-B
[9]   RELATION BETWEEN VENTRICULOARTERIAL COUPLING AND MYOCARDIAL ENERGETICS IN PATIENTS WITH IDIOPATHIC DILATED CARDIOMYOPATHY [J].
ISHIHARA, H ;
YOKOTA, M ;
SOBUE, T ;
SAITO, H .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 23 (02) :406-416
[10]   EFFECTIVE ARTERIAL ELASTANCE AS INDEX OF ARTERIAL VASCULAR LOAD IN HUMANS [J].
KELLY, RP ;
TING, CT ;
YANG, TM ;
LIU, CP ;
MAUGHAN, WL ;
CHANG, MS ;
KASS, DA .
CIRCULATION, 1992, 86 (02) :513-521