True-lumen collapse in aortic dissection - Part I. Evaluation of causative factors in phantoms with pulsatile flow

被引:91
作者
Chung, JW [1 ]
Elkins, C [1 ]
Sakai, T [1 ]
Kato, N [1 ]
Vestring, T [1 ]
Semba, CP [1 ]
Slonim, SM [1 ]
Dake, MD [1 ]
机构
[1] Stanford Univ, Med Ctr, Div Cardiovasc Intervent Radiol, Stanford Vasc Ctr, Palo Alto, CA 94304 USA
关键词
aorta; dissection; flow dynamics; stenosis or obstruction; US; phantoms;
D O I
10.1148/radiology.214.1.r00ja3287
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To investigate the causative factors in true-lumen collapse in a model of aortic dissection. MATERIALS AND METHODS: Phantoms with an aortic arch, true and false lumina with abdominal branch vessels, and a distal bifurcation were used to model a Stanford type B aortic dissection. The effects of anatomic factors (entry-tear size, branch-vessel flow distribution, fenestrations, distal reentry communication) and physiologic factors (peripheral resistance in the branch vessels, pump output and rate, vascular compliance) on true-lumen collapse were investigated. The morphology of the true lumen was observed. Branch pressures and flow rates were measured. RESULTS: True-lumen collapse was induced and was exacerbated by an increase-in the size of the entry tear, a decrease in the false-lumen outflow caused by occluding the false-lumen branch vessels, and an increase in the true-lumen outflow caused by lowering the peripheral resistance in true-lumen branch vessels.: Two kinds of true-lumen collapse depended on pump output. With low pump output and low outflow resistance from the true lumen, the true lumen collapsed. With high pump output and low inflow resistance in the false lumen, the true lumen Was compressed. Distal reentry communication between the true and false limbs was more effective than aortic fenestrations in preventing true-lumen collapse. CONCLUSION: True-lumen collapse in this dissection model strongly depends on the difference in the ratios of inflow capacity to outflow capacity in the true and false lumina. Both anatomic and physiologic factors can affect-true-lumen collapse.
引用
收藏
页码:87 / 98
页数:12
相关论文
共 7 条
[1]   VASCULAR COMPLICATIONS ASSOCIATED WITH SPONTANEOUS AORTIC DISSECTION [J].
CAMBRIA, RP ;
BREWSTER, DC ;
GERTLER, J ;
MONCURE, AC ;
GUSBERG, R ;
TILSON, MD ;
DARLING, RC ;
HAMMOND, G ;
MEGERMAN, J ;
ABBOTT, WM .
JOURNAL OF VASCULAR SURGERY, 1988, 7 (02) :199-209
[2]   TREATMENT OF PATIENTS WITH AORTIC DISSECTION PRESENTING WITH PERIPHERAL VASCULAR COMPLICATIONS [J].
FANN, JI ;
SARRIS, GE ;
MITCHELL, RS ;
SHUMWAY, NE ;
STINSON, EB ;
OYER, PE ;
MILLER, DC .
ANNALS OF SURGERY, 1990, 212 (06) :705-713
[3]  
SARRIS GE, 1992, LONG TERM RESULTS VA, P111
[4]   True lumen obliteration in complicated aortic dissection: Endovascular treatment [J].
Slonim, SM ;
Nyman, UR ;
Semba, CP ;
Miller, DC ;
Mitchell, RS ;
Dake, MD .
RADIOLOGY, 1996, 201 (01) :161-166
[5]   The dissected aorta .3. Anatomy and radiologic diagnosis of branch-vessel compromise [J].
Williams, DM ;
Lee, DY ;
Hamilton, BH ;
Marx, MV ;
Narasimham, DL ;
Kazanjian, SN ;
Prince, MR ;
Andrews, JC ;
Cho, KJ ;
Deeb, GM .
RADIOLOGY, 1997, 203 (01) :37-44
[6]   The dissected aorta: Percutaneous treatment of ischemic complications - Principles and results [J].
Williams, DM ;
Lee, DY ;
Hamilton, BH ;
Marx, MV ;
Narasimham, DL ;
Kazanjian, SN ;
Prince, MR ;
Andrews, JC ;
Cho, KJ ;
Deeb, GM .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1997, 8 (04) :605-625
[7]   The dissected aorta .1. Early anatomic changes in an in vitro model [J].
Williams, DM ;
LePage, MA ;
Lee, DY .
RADIOLOGY, 1997, 203 (01) :23-31