Automated cardiac output measurement by transesophageal color Doppler echocardiography

被引:12
作者
Akamatsu, S [1 ]
Oda, A [1 ]
Terazawa, E [1 ]
Yamamoto, T [1 ]
Ohata, H [1 ]
Michino, T [1 ]
Dohi, S [1 ]
机构
[1] Gifu Univ, Sch Med, Dept Anesthesiol & Crit Care Med, Gifu 5008705, Japan
关键词
D O I
10.1213/01.ANE.0000112314.94283.24
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Automated cardiac output measurement (ACOM), which integrates digital color Doppler velocities in space and in time, has been validated using transthoracic echocardiography but has not been tested using transesophageal echocardiography (TEE). Therefore, we determined the feasibility of the ACOM method by TEE in 36 patients undergoing cardiovascular surgery. Regions of interest for ACOM were placed within a color sector across the main pulmonary artery (PA), the mitral annulus, and the left ventricular outflow tract. Cardiac output was determined from the PA flow, the mitral flow, and the left ventricular ejection flow at each view using the ACOM method. We compared measurements of cardiac output derived from the ACOM method with measurements simultaneously obtained by thermodilution (TD). In the mitral flow analysis, the values derived from ACOM correlated well with those from TD (R-2 = 0.85; mean difference = 0.01 0.58 L/min in the 2-chamber view; R-2 = 0.78; mean difference = -0.10 +/- 0.68 L/min in the 4-chamber view). In the PA flow analysis, the values derived from ACOM did not correlate with those from TD (R-2 = 0.30). In the left ventricular outflow tract analysis, it was very difficult to obtain the optimal view (44%) in which color Doppler flow signals adequately appeared. Using the ACOM method, we obtained good correlation and agreement for cardiac output measurements in the mitral flow analysis compared with TD. The ACOM method is a practical and rapid method to measure cardiac output by TEE analysis of mitral flow.
引用
收藏
页码:1232 / 1238
页数:7
相关论文
共 24 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   DETERMINATION OF CARDIAC-OUTPUT BY TRANS-CUTANEOUS CONTINUOUS-WAVE ULTRASONIC DOPPLER COMPUTER [J].
CHANDRARATNA, PA ;
NANNA, M ;
MCKAY, C ;
NIMALASURIYA, A ;
SWINNEY, R ;
ELKAYAM, U ;
RAHIMTOOLA, SH .
AMERICAN JOURNAL OF CARDIOLOGY, 1984, 53 (01) :234-237
[3]  
DARMON PL, 1994, ANESTHESIOLOGY, V80, P796, DOI 10.1097/00000542-199404000-00011
[4]   INFLUENCE OF SAMPLING SITE AND FLOW AREA ON CARDIAC-OUTPUT MEASUREMENTS BY DOPPLER ECHOCARDIOGRAPHY [J].
DITTMANN, H ;
VOELKER, W ;
KARSCH, KR ;
SEIPEL, L .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 10 (04) :818-823
[5]   THE EFFECT OF VARIATIONS ON PULSED DOPPLER SAMPLING SITE ON CALCULATION OF CARDIAC-OUTPUT - AN EXPERIMENTAL-STUDY IN OPEN-CHEST DOGS [J].
FISHER, DC ;
SAHN, DJ ;
FRIEDMAN, MJ ;
LARSON, D ;
VALDESCRUZ, LM ;
HOROWITZ, S ;
GOLDBERG, SJ ;
ALLEN, HD .
CIRCULATION, 1983, 67 (02) :370-376
[6]   Automated assessment of mitral regurgitant volume and regurgitant fraction by a newly developed digital color Doppler velocity profile integration method [J].
Hozumi, T ;
Yoshida, K ;
Akasaka, T ;
Takagi, T ;
Yamamuro, A ;
Yagi, T ;
Yoshikawa, J .
AMERICAN JOURNAL OF CARDIOLOGY, 1997, 80 (10) :1325-1330
[7]   THE EFFECTS OF SAMPLING SITE ON THE 2-DIMENSIONAL ECHO-DOPPLER DETERMINATION OF CARDIAC-OUTPUT [J].
LABOVITZ, AJ ;
BUCKINGHAM, TA ;
HABERMEHL, K ;
NELSON, J ;
KENNEDY, HL ;
WILLIAMS, GA .
AMERICAN HEART JOURNAL, 1985, 109 (02) :327-332
[8]  
LATSON TW, 1993, ANESTHESIOLOGY, V79, P1233
[9]   RELATIONSHIP OF REGIONAL WALL MOTION ABNORMALITIES TO HEMODYNAMIC INDEXES OF MYOCARDIAL OXYGEN-SUPPLY AND DEMAND IN PATIENTS UNDERGOING CABG SURGERY [J].
LEUNG, JM ;
OKELLY, BF ;
MANGANO, DT .
ANESTHESIOLOGY, 1990, 73 (05) :802-814
[10]   PULSED DOPPLER ECHOCARDIOGRAPHIC DETERMINATION OF STROKE VOLUME AND CARDIAC-OUTPUT - CLINICAL VALIDATION OF 2 NEW METHODS USING THE APICAL WINDOW [J].
LEWIS, JF ;
KUO, LC ;
NELSON, JG ;
LIMACHER, MC ;
QUINONES, MA .
CIRCULATION, 1984, 70 (03) :425-431