Biological performance of a new β-TCP/PLLA composite material for applications in spine surgery:: In vitro and in vivo studies

被引:61
作者
Aunoble, Stephane
Clement, Denis
Frayssinet, Patrick
Harmand, Marie Francois
Le Huec, Jean Charles
机构
[1] Univ Bordeaux 2, Spine Unit, DETERCA Lab, F-33076 Bordeaux, France
[2] Dept SBM, ZI Monge, F-65100 Lourdes, France
[3] URODELIA, F-31470 St Lys, France
[4] LEMI, Technopole Montesquieu, F-33650 Martillac, France
关键词
tricalcium phosphate; bone substitutes; spine arthrodesis;
D O I
10.1002/jbm.a.30749
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
The objective of this research was to carry out an in vitro and in vivo study of the biological performance of PLLA/beta-TCP composite materials, to estimate the scope of their potential applications in bone surgery. Samples with increasing beta-TCP (0-60% w/w) contents were processed by injection molding. The in vitro study consisted of an evaluation of inflammatory potential by assaying the IL-1 alpha secreted by monocytes, and then cell proliferation (counting) and phenotype expression (PAL and I collagen) in human osteogenous cells. The in vivo study was carried out using cylindrical implants of composite materials composed of composite materials containing 0 or 60% beta-TCP and pure P-TCP, respectively. The implants were inserted in femoral sites in rabbits, using the Kathagen protocol. Each animal received a 60% implant, with either a 0 or a 100% implant in the contralateral femur, so that the materials could be compared with one another. Five animals were examined for each material and implantation period, giving a total of 30 animals. This study showed that adding increasing percentages of beta-TCP to a lactic acid polymer matrix stimulated the proliferation of human osteogenous cells and synthesis of the extracellular bone matrix in a dose-dependent manner. In vivo results indicate that, in comparison with pure PLA, tricalcium phosphate-containing composite materials had faster degradation kinetics, caused less inflammatory reaction, and promoted contact osteogenesis. The composite material containing 60% beta-TCP demonstrated a similar performance to pure tricalcium phosphate bone grafts in terms of osteogenesis, and is apparently compatible with the production of intra-osseous implants for situations representing high levels of mechanical strain. (c) 2006 Wiley Periodicals, Inc.
引用
收藏
页码:416 / 422
页数:7
相关论文
共 52 条
[1]
Agrawal CM, 1997, J BIOMED MATER RES, V38, P105, DOI 10.1002/(SICI)1097-4636(199722)38:2<105::AID-JBM4>3.0.CO
[2]
2-U
[3]
FOREIGN-BODY REACTIONS TO RESORBABLE POLY(L-LACTIDE) BONE PLATES AND SCREWS USED FOR THE FIXATION OF UNSTABLE ZYGOMATIC FRACTURES [J].
BERGSMA, EJ ;
ROZEMA, FR ;
BOS, RRM ;
DEBRUIJN, WC .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1993, 51 (06) :666-670
[4]
LATE DEGRADATION TISSUE-RESPONSE TO POLY(L-LACTIDE) BONE PLATES AND SCREWS [J].
BERGSMA, JE ;
DEBRUIJN, WC ;
ROZEMA, FR ;
BOS, RRM ;
BOERING, G .
BIOMATERIALS, 1995, 16 (01) :25-31
[5]
Bonnevialle P, 2002, REV CHIR ORTHOP, V88, P486
[6]
DEGRADATION OF AND TISSUE REACTION TO BIODEGRADABLE POLY(L-LACTIDE) FOR USE AS INTERNAL-FIXATION OF FRACTURES - A STUDY IN RATS [J].
BOS, RRM ;
ROZEMA, FR ;
BOERING, G ;
NIJENHUIS, AJ ;
PENNINGS, AJ ;
VERWEY, AB ;
NIEUWENHUIS, P ;
JANSEN, HWB .
BIOMATERIALS, 1991, 12 (01) :32-36
[7]
Osteoarthritis of the ankle after foreign-body reaction to absorbable pins and screws -: A three- to nine-year follow-up study [J].
Böstman, OM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (02) :333-338
[8]
Böstman OM, 2000, CLIN ORTHOP RELAT R, P216
[9]
EVALUATION OF ABSORBABLE POLY(ORTHO ESTERS) FAR USE IN SURGICAL IMPLANTS [J].
DANIELS, AU ;
ANDRIANO, KP ;
SMUTZ, WP ;
CHANG, MKO ;
HELLER, J .
JOURNAL OF APPLIED BIOMATERIALS, 1994, 5 (01) :51-64
[10]
Flahiff CM, 1996, J BIOMED MATER RES, V32, P419