Broadband phase correction of FT-ICR mass spectra via simultaneous excitation and detection

被引:50
作者
Beu, SC
Blakney, GT
Quinn, JP
Hendrickson, CL [1 ]
Marshall, AG
机构
[1] Natl High Magnet Field Lab, Ion Cyclotron Resonance Program, Tallahassee, FL 32310 USA
[2] SC Beu Consulting, Austin, TX 78750 USA
[3] Florida State Univ, Dept Chem & Biochem, Tallahassee, FL 32310 USA
关键词
D O I
10.1021/ac049733i
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In typical Fourier transform ion cyclotron resonance (FT-ICR) mass spectra, temporally dispersed excitation and the delay between excitation and detection result in continuous variation of signal phase with frequency in the detected time-domain ion signal. The complex frequency-domain spectrum of such a signal is a linear combination of absorption- and dispersion-mode spectral components with corresponding asymmetric peaks. For this reason, magnitude-mode spectral display is usually employed to yield a phase-independent uniform and symmetrical peak shape at the expense of spectral resolution. In this work, we implement simultaneous excitation and detection to enable Fourier deconvolution to recover absorption-mode spectra for both low- and high-field FT-ICR instruments. These spectra yield resolving power improvement factors approaching the maximum theoretical limit of 2.0, as well as reduction in frequency assignment errors relative to conventional magnitude-mode spectra. The Fourier deconvolution procedure has the additional benefit of correcting for spectral variation resulting from nonuniform power distribution over the excitation bandwidth and the potential benefit of providing useful diagnostic information for interpretation of experimental performance.
引用
收藏
页码:5756 / 5761
页数:6
相关论文
共 31 条
[1]   FOURIER SPECTROSCOPY AND CAUSALITY PRINCIPLE [J].
BARTHOLD.E ;
ERNST, RR .
JOURNAL OF MAGNETIC RESONANCE, 1973, 11 (01) :9-19
[2]  
Beu S. C., 1999, P 47 ASMS C MASS SPE
[3]  
Beu S. C., 1998, P 46 ASMS C MASS SPE, P502
[4]  
BEU SC, 2003, P 51 ASMS C MASS SPE
[5]   FREQUENCY (MASS) ERRORS AND PHASE DEPENDENCE IN MAGNITUDE-MODE APODIZED FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE-SPECTRA [J].
CHOW, KH ;
COMISAROW, MB .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1989, 89 (2-3) :187-203
[6]   SELECTIVE-PHASE ION-CYCLOTRON RESONANCE SPECTROSCOPY [J].
COMISAROW, MB ;
MARSHALL, AG .
CANADIAN JOURNAL OF CHEMISTRY, 1974, 52 (10) :1997-1999
[7]  
Craig E C, 1987, Rapid Commun Mass Spectrom, V1, P33, DOI 10.1002/rcm.1290010209
[8]   CYCLOTRON ORBITAL RADIUS DETERMINATION IN FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY [J].
GROSSHANS, PB ;
MARSHALL, AG .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1992, 115 (01) :1-19
[9]   ELIMINATION OF FREQUENCY DRIFT FROM FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTRA BY DIGITAL QUADRATURE HETERODYNING - ULTRAHIGH MASS RESOLVING POWER FOR LASER-DESORBED MOLECULES [J].
GUAN, SH ;
WAHL, MC ;
MARSHALL, AG .
ANALYTICAL CHEMISTRY, 1993, 65 (24) :3647-3653
[10]   Effect of ion-neutral collision mechanism on the trapped-ion equation of motion: a new mass spectral line shape for high-mass trapped ions [J].
Guan, SH ;
Li, GZ ;
Marshall, AG .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1997, 167 :185-193