The effects of ex vivo handling procedures on the near-infrared Raman spectra of normal mammalian tissues

被引:82
作者
Shim, MG
Wilson, BC
机构
[1] PRINCESS MARGARET HOSP,ONTARIO CANC INST,DEPT MED PHYS,TORONTO,ON M5G 2M9,CANADA
[2] UNIV TORONTO,DEPT MED BIOPHYS,TORONTO,ON,CANADA
关键词
D O I
10.1111/j.1751-1097.1996.tb05671.x
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Recent studies in the literature have investigated the feasibility of tissue diagnostics based on Raman spectroscopy. The majority of these compare the ex vivo spectra of normal and diseased tissue. Due to the time lapse between tissue excision and spectroscopic examination, samples must be frozen or otherwise preserved to maintain their native biochemical states. In order to establish optimum procedures for ex vivo Raman spectroscopy of tissue, the effects of tissue drying, formalin fixing, snap freezing, tissue freezing in optimal cutting temperature (OCT) medium and extended post-thaw durations were studied to determine if any of these handling procedures introduced spectral artifacts. Experiments on representative tissues indicated that tissue heating due to the excitation light did not change the spectra significantly. With minor exceptions, OCT and formalin did not contaminate tissue spectra, so that samples stored for histological examination could also be studied with Raman spectroscopy. Tissue dehydration caused disruption of the protein vibrational modes, which caused spectral artifacts. It is concluded that ex vivo tissue samples should be frozen in OCT. Prior to spectral analysis, the tissue should then be acclimatized at room temperature in phosphate-buffered saline (PBS) and immersed in PBS during spectroscopic examination.
引用
收藏
页码:662 / 671
页数:10
相关论文
共 26 条
[1]  
ANDREOLA S, 1988, LASER SURG MED, V8, P142
[2]   ANALYSIS OF TISSUE OPTICAL COEFFICIENTS USING AN APPROXIMATE EQUATION VALID FOR COMPARABLE ABSORPTION AND SCATTERING [J].
ARNFIELD, MR ;
MATHEW, RP ;
TULIP, J ;
MCPHEE, MS .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (06) :1219-1230
[3]   RAPID NEAR-INFRARED RAMAN-SPECTROSCOPY OF HUMAN TISSUE WITH A SPECTROGRAPH AND CCD DETECTOR [J].
BARAGA, JJ ;
FELD, MS ;
RAVA, RP .
APPLIED SPECTROSCOPY, 1992, 46 (02) :187-190
[4]   A REVIEW OF THE OPTICAL-PROPERTIES OF BIOLOGICAL TISSUES [J].
CHEONG, WF ;
PRAHL, SA ;
WELCH, AJ .
IEEE JOURNAL OF QUANTUM ELECTRONICS, 1990, 26 (12) :2166-2185
[5]  
CHIEN MC, 1975, BIOCHEMISTRY-US, V14, P4385
[6]  
DVAIES JED, 1975, CHEM PHYS LIPIDS, V15, P45
[7]   FURANOID FATTY-ACIDS FROM FISH LIPIDS [J].
GLASS, RL ;
KRICK, TP ;
SAND, DM ;
RAHN, CH ;
SCHLENK, H .
LIPIDS, 1975, 10 (11) :695-702
[8]  
Harada I., 1986, Spectroscopy of Biological Systems: Advances in Infraredand Raman Spectroscopy, V13, P113
[9]   APPLICATIONS OF THE 1-D DIFFUSION-APPROXIMATION TO THE OPTICS OF TISSUES AND TISSUE PHANTOMS [J].
KARAGIANNES, JL ;
ZHANG, Z ;
GROSSWEINER, B ;
GROSSWEINER, LI .
APPLIED OPTICS, 1989, 28 (12) :2311-2317
[10]   APPLICATION OF NEAR-INFRARED FOURIER-TRANSFORM RAMAN-SPECTROSCOPY IN MEDICAL-RESEARCH [J].
KELLER, S ;
SCHRADER, B ;
HOFFMANN, A ;
SCHRADER, W ;
METZ, K ;
REHLAENDER, A ;
PAHNKE, J ;
RUWE, M ;
BUDACH, W .
JOURNAL OF RAMAN SPECTROSCOPY, 1994, 25 (7-8) :663-671