Intravascular ultrasonic predictors of angiographic restenosis after long coronary stenting

被引:29
作者
Hong, MK
Park, SW
Mintz, GS
Lee, NH
Lee, CW
Kim, JJ
Park, SJ
机构
[1] Univ Ulsan, Coll Med, Dept Internal Med, Ctr Cardiovasc,Asan Med Ctr,Songpa Gu, Seoul, South Korea
[2] Washington Cardiol Ctr, Washington, DC USA
关键词
D O I
10.1016/S0002-9149(99)00769-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The intravascular ultrasound (IVUS) criteria for stent optimization have not been determined in stenting long lesions. We evaluated the predictors of angiographic restenosis and compared it with stent lumen cross-sectional area (CSA) and stent length between short (stent length <20 mm) and long (greater than or equal to 20 mm) coronary stenting. IVUS-guided coronary stenting was successfully performed in 285 consecutive patients with 304 native coronary lesions. Six-month follow-up angiogram was performed in 236 patients (82.8%) with 246 lesions (80.9%). Results were evaluated using conventional (clinical, angiographic, and IVUS) methods. The overall angiographic restenosis rate was 22.8% (56 of 246 lesions) (short stent 17.6% vs long stent 32.2%, p 0.009). Using multivariate logistic regression analysis, the independent predictors of angiographic restenosis were the IVUS stent lumen CSA (odds ratio 1.51, 95% confidence intervals 1.18 to 1.92, p = 0.001) and stent length (odds ratio 0.95, 95% confidence intervals 0.91 to 1.00, p = 0.039). The angiographic restenosis rate was 54.8% for stent lumen CSA of <5.0 mm(2) (short stent 37.5% vs long stent 73.3%, p = 0.049), 27.4% for CSA between 5.0 and 7.0 mm(2) (short stent 24.1% vs long stent 31.7%, p = 0.409), 10.5% for CSA between 7.0 and 9.0 mm(2) (short stent 10.0% vs long stent 12.5%, p = 0.772), and 11.4% for stent lumen CSA of greater than or equal to 9.0 mm(2) (short stent 10.4% vs long stent 13.3%, p = 0.767) (p = 0.001). Compared with short coronary stenting, long coronary stenting is effective treatment modality to cover long lesions with comparable long-term clinical outcomes in cases of stent lumen CSA of greater than or equal to 7.0 mm(2). Regardless of the stent length, the most important factor determining angiographic restenosis was the IVUS stent lumen CSA in relatively large coronary artery lesions. (C) 2000 by Excerpta Medica, Inc.
引用
收藏
页码:441 / 445
页数:5
相关论文
共 27 条
  • [1] Randomised trial of excimer laser angioplasty versus balloon angioplasty for treatment of obstructive coronary artery disease
    Appelman, YEA
    Piek, JJ
    Strikwerda, S
    Tijssen, JGP
    deFeyter, PJ
    David, GK
    Serruys, PW
    Margolis, JR
    Koelemay, MJ
    vanSwijndregt, EWJM
    Koolen, JJ
    [J]. LANCET, 1996, 347 (8994) : 79 - 84
  • [2] INTRACORONARY STENTING WITHOUT ANTICOAGULATION ACCOMPLISHED WITH INTRAVASCULAR ULTRASOUND GUIDANCE
    COLOMBO, A
    HALL, P
    NAKAMURA, S
    ALMAGOR, Y
    MAIELLO, L
    MARTINI, G
    GAGLIONE, A
    GOLDBERG, SL
    TOBIS, JM
    [J]. CIRCULATION, 1995, 91 (06) : 1676 - 1688
  • [3] Eeckhout E, 1996, CATHETER CARDIO DIAG, V39, P302
  • [4] RESTENOSIS AFTER PLACEMENT OF PALMAZ-SCHATZ STENTS IN NATIVE CORONARY-ARTERIES - INITIAL RESULTS OF A MULTICENTER EXPERIENCE
    ELLIS, SG
    SAVAGE, M
    FISCHMAN, D
    BAIM, DS
    LEON, M
    GOLDBERG, S
    HIRSHFELD, JW
    CLEMAN, MW
    TEIRSTEIN, PS
    WALKER, C
    BAILEY, S
    BUCHBINDER, M
    TOPOL, EJ
    SCHATZ, RA
    [J]. CIRCULATION, 1992, 86 (06) : 1836 - 1844
  • [5] A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE
    FISCHMAN, DL
    LEON, MB
    BAIM, DS
    SCHATZ, RA
    SAVAGE, MP
    PENN, I
    DETRE, K
    VELTRI, L
    RICCI, D
    NOBUYOSHI, M
    CLEMAN, M
    HEUSER, R
    ALMOND, D
    TEIRSTEIN, PS
    FISH, RD
    COLOMBO, A
    BRINKER, J
    MOSES, J
    SHAKNOVICH, A
    HIRSHFELD, J
    BAILEY, S
    ELLIS, S
    RAKE, R
    GOLDBERG, S
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) : 496 - 501
  • [6] HAUDE M, 1991, BRIT HEART J, V66, P337
  • [7] RESTENOSIS AFTER CORONARY ANGIOPLASTY - A MULTIVARIATE STATISTICAL-MODEL TO RELATE LESION AND PROCEDURE VARIABLES TO RESTENOSIS
    HIRSHFELD, JW
    SCHWARTZ, JS
    JUGO, R
    MACDONALD, RG
    GOLDBERG, S
    SAVAGE, MP
    BASS, TA
    VETROVEC, G
    COWLEY, M
    TAUSSIG, AS
    WHITWORTH, HB
    MARGOLIS, JR
    HILL, JA
    PEPINE, CJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 18 (03) : 647 - 656
  • [8] Intravascular ultrasound predictors of angiographic restenosis in lesions treated with Palmaz-Schatz stents
    Hoffmann, R
    Mintz, GS
    Mehran, R
    Pichard, AD
    Kent, KM
    Satler, LF
    Popma, JJ
    Wu, HS
    Leon, MB
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (01) : 43 - 49
  • [9] Intravascular ultrasound findings in stenting of unprotected left main coronary artery stenosis
    Hong, MK
    Park, SW
    Lee, CW
    Kang, DH
    Song, JK
    Kim, JJ
    Park, SJ
    Hong, MK
    Mintz, GS
    Leon, MB
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1998, 82 (05) : 670 - +
  • [10] Angiographic and intravascular ultrasound predictors of in-stent restenosis
    Kasaoka, S
    Tobis, JM
    Akiyama, T
    Reimers, B
    Di Mario, C
    Wong, ND
    Colombo, A
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (06) : 1630 - 1635