Precise frequency transfer through a fiber network by use of 1.5-μm mode-locked sources

被引:54
作者
Holman, KW [1 ]
Jones, DJ
Hudson, DD
Ye, J
机构
[1] Natl Inst Stand & Technol, Joint Inst Lab Astrophys, Boulder, CO 80309 USA
[2] Univ Colorado, Boulder, CO 80309 USA
关键词
D O I
10.1364/OL.29.001554
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We report the precise transfer of radio-frequency signals by use of the pulse repetition frequency of mode-locked laser sources at 1.5 mum transmitting through a fiber network. The. passive transfer instability through a 6.9-km fiber is, below 3 X 10(-14) at 1 s, which. is comparable with the optical carrier-frequency transfer of a narrow-linewidth cw laser. The instability of the measurement system is below 7 X 10(-15) at 1 s. It is noted that the pulsed mode of operation offers almost an order-of-magnitude improvement in stability at I s over that with a sinusoidal amplitude. modulation on An optical carrier. (C) 2004 Optical Society of America.
引用
收藏
页码:1554 / 1556
页数:3
相关论文
共 5 条
[1]   An optical clock based on a single trapped 199Hg+ ion [J].
Diddams, SA ;
Udem, T ;
Bergquist, JC ;
Curtis, EA ;
Drullinger, RE ;
Hollberg, L ;
Itano, WM ;
Lee, WD ;
Oates, CW ;
Vogel, KR ;
Wineland, DJ .
SCIENCE, 2001, 293 (5531) :825-828
[2]   Orthogonal control of the frequency comb dynamics of a mode-locked laser diode [J].
Holman, KW ;
Jones, DJ ;
Ye, J ;
Ippen, EP .
OPTICS LETTERS, 2003, 28 (23) :2405-2407
[3]   Microwave interferometry: Application to precision measurements and noise reduction techniques [J].
Ivanov, EN ;
Tobar, ME ;
Woode, RA .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1998, 45 (06) :1526-1536
[4]   Delivery of high-stability optical and microwave frequency standards over an optical fiber network [J].
Ye, J ;
Peng, JL ;
Jones, RJ ;
Holman, KW ;
Hall, JL ;
Jones, DJ ;
Diddams, SA ;
Kitching, J ;
Bize, S ;
Bergquist, JC ;
Hollberg, LW ;
Robertsson, L ;
Ma, LS .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 2003, 20 (07) :1459-1467
[5]   Molecular iodine clock [J].
Ye, J ;
Ma, LS ;
Hall, JL .
PHYSICAL REVIEW LETTERS, 2001, 87 (27) :270801-270801