Accuracy of electrocardiogram interpretation by cardiologists in the setting of incorrect computer analysis

被引:43
作者
Anh, Daejoon
Krishnan, Subramaniam
Bogun, Frank [1 ]
机构
[1] Univ Michigan, Div Cardiol, Ann Arbor, MI 48109 USA
[2] Henry Ford Hosp, Div Cardiol, Detroit, MI 48202 USA
关键词
D O I
10.1016/j.jelectrocard.2006.02.002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Overreading of 12 lead electrocardiograms (ECGs) is required to circumvent errors of computerized ECG interpretation. The accuracy of the overreading physician's interpretation of ECGs that were incorrectly read as atrial fibrillation by a computer algorithm has not been systematically examined. Methods: A total of 2298 ECGs with the computerized interpretation of atrial fibrillation from 1085 patients were analyzed by 2 electrophysiologists, who identified 442 ECGs (19%) from 382 patients (35%) that were incorrectly interpreted as atrial fibrillation. Charts were reviewed to determine the interpretation of the ECG by the ordering physician (primary reader) and the overreading cardiologist. Results: Cardiologists as primary readers more often corrected the misinterpreted ECGs as compared with internists, emergency physicians, or other specialists (94% vs 71%, P < .001). Surprisingly, interpretations by cardiologists as primary readers were more accurate than the interpretation provided by overreading cardiologists (94% vs 72%, P < .001). Conclusion: Knowledge of an individual patient on whom an ECG is ordered may result in a more critical rhythm assessment and might account for the higher accuracy of rhythm interpretation by the cardiologist as compared with the interpretation by the overreading cardiologist who is lacking relevant clinical information. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:343 / 345
页数:3
相关论文
共 9 条
[1]   Misdiagnosis of atrial fibrillation and its clinical consequences [J].
Bogun, F ;
Anh, D ;
Kalahasty, G ;
Wissner, E ;
Serhal, CB ;
Bazzi, R ;
Weaver, WD ;
Schuger, C .
AMERICAN JOURNAL OF MEDICINE, 2004, 117 (09) :636-642
[2]   Impact of a clinical scenario on accuracy of electrocardiogram interpretation [J].
Hatala, R ;
Norman, GR ;
Brooks, LR .
JOURNAL OF GENERAL INTERNAL MEDICINE, 1999, 14 (02) :126-129
[3]   Overreliance on computerized algorithms to interpret electrocardiograms [J].
Hongo, RH ;
Goldschlager, N .
AMERICAN JOURNAL OF MEDICINE, 2004, 117 (09) :706-708
[4]   Clinical consequences of electrocardiographic artifact mimicking ventricular tachycardia [J].
Knight, BP ;
Pelosi, F ;
Michaud, GF ;
Strickberger, SA ;
Morady, F .
NEW ENGLAND JOURNAL OF MEDICINE, 1999, 341 (17) :1270-1274
[5]   Physician interpretation of electrocardiographic artifact that mimics ventricular tachycardia [J].
Knight, BP ;
Pelosi, F ;
Michaud, GF ;
Strickberger, SA ;
Morady, F .
AMERICAN JOURNAL OF MEDICINE, 2001, 110 (05) :335-338
[6]  
Pryor W W, 1996, J S C Med Assoc, V92, P339
[7]  
Reddy BRS, 1997, J ELECTROCARDIOL, V30, P28
[8]   Computer treason: Intraobserver variability of an electrocardiographic computer system [J].
Spodick, DH ;
Bishop, RL .
AMERICAN JOURNAL OF CARDIOLOGY, 1997, 80 (01) :102-&
[9]   MULTIFOCAL ATRIAL ARRHYTHMIA - A FREQUENT MISDIAGNOSIS - A CORRELATIVE STUDY USING THE COMPUTERIZED ECG [J].
VARRIALE, P ;
DAVID, W ;
CHRYSSOS, BE .
CLINICAL CARDIOLOGY, 1992, 15 (05) :343-346