Dual-micro-ESI source for precise mass determination on a quadrupole time-of-flight mass spectrometer for genomic and proteomic applications

被引:22
作者
Flora, JW [1 ]
Null, AP [1 ]
Muddiman, DC [1 ]
机构
[1] Virginia Commonwealth Univ, Dept Chem, Richmond, VA 23284 USA
关键词
electrospray; time-of-flight; mass spectrometry; internal calibration; accurate mass;
D O I
10.1007/s00216-002-1357-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A universal dual-electrospray (ESI) source is demonstrated on a quadrupole orthogonal-accelerated time-of-flight mass spectrometer (Q-ToF-MS) for both genomic and proteomic applications. This facile source modification enables internal calibration for consistent mass measurements by a mainstream MS platform and requires no mixing of analyte and calibrant prior to ion formation. In this report, the dual-sprayer is demonstrated in the negative-ion mode for internal calibration of polymerase chain reaction (PCR) amplicons generated from synthetic and genomic templates as well as a proteolytic digest of a naturally phosphorylated protein. For all PCR amplicons, experimentally determined average mass measurements are well within the instrument specifications of better than 0.01%. For the proteolytic fragments of the phosphoprotein, average mass errors of the isotopically resolved peptides are better than 10 ppm.
引用
收藏
页码:538 / 546
页数:9
相关论文
共 87 条
[1]   Mass spectrometry in proteomics [J].
Aebersold, R ;
Goodlett, DR .
CHEMICAL REVIEWS, 2001, 101 (02) :269-295
[2]   CHEMICAL MASS OF CARBON IN PROTEINS [J].
BEAVIS, RC .
ANALYTICAL CHEMISTRY, 1993, 65 (04) :496-497
[3]   Exact mass measurements using a 7 Tesla Fourier transform ion cyclotron resonance mass spectrometer in a good laboratory practices-regulated environment [J].
Burton, RD ;
Matuszak, KP ;
Watson, CH ;
Eyler, JR .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1999, 10 (12) :1291-1297
[4]  
Cao P, 1998, RAPID COMMUN MASS SP, V12, P864, DOI 10.1002/(SICI)1097-0231(19980715)12:13<864::AID-RCM244>3.0.CO
[5]  
2-G
[6]   Role of accurate mass measurement (±10 ppm) in protein identification strategies employing MS or MS MS and database searching [J].
Clauser, KR ;
Baker, P ;
Burlingame, AL .
ANALYTICAL CHEMISTRY, 1999, 71 (14) :2871-2882
[7]   Utility of accurate mass tags for proteome-wide protein identification [J].
Conrads, TP ;
Anderson, GA ;
Veenstra, TD ;
Pasa-Tolic, L ;
Smith, RD .
ANALYTICAL CHEMISTRY, 2000, 72 (14) :3349-3354
[8]  
Crouse J., 1987, FOCUS, V9, P3
[9]   Characterization of DNA oligonucleotides by coupling of capillary zone electrophoresis to electrospray ionization Q-TOF mass spectrometry [J].
Deforce, DLD ;
Raymackers, J ;
Meheus, L ;
Van Wijnendaele, F ;
De Leenheer, A ;
Van den Eeckhout, EG .
ANALYTICAL CHEMISTRY, 1998, 70 (14) :3060-3068
[10]   Electrospray as an ionisation method for mass spectrometry [J].
Dülcks, T ;
Juraschek, R .
JOURNAL OF AEROSOL SCIENCE, 1999, 30 (07) :927-943