Dual-micro-ESI source for precise mass determination on a quadrupole time-of-flight mass spectrometer for genomic and proteomic applications

被引:22
作者
Flora, JW [1 ]
Null, AP [1 ]
Muddiman, DC [1 ]
机构
[1] Virginia Commonwealth Univ, Dept Chem, Richmond, VA 23284 USA
关键词
electrospray; time-of-flight; mass spectrometry; internal calibration; accurate mass;
D O I
10.1007/s00216-002-1357-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A universal dual-electrospray (ESI) source is demonstrated on a quadrupole orthogonal-accelerated time-of-flight mass spectrometer (Q-ToF-MS) for both genomic and proteomic applications. This facile source modification enables internal calibration for consistent mass measurements by a mainstream MS platform and requires no mixing of analyte and calibrant prior to ion formation. In this report, the dual-sprayer is demonstrated in the negative-ion mode for internal calibration of polymerase chain reaction (PCR) amplicons generated from synthetic and genomic templates as well as a proteolytic digest of a naturally phosphorylated protein. For all PCR amplicons, experimentally determined average mass measurements are well within the instrument specifications of better than 0.01%. For the proteolytic fragments of the phosphoprotein, average mass errors of the isotopically resolved peptides are better than 10 ppm.
引用
收藏
页码:538 / 546
页数:9
相关论文
共 87 条
[81]   Genotyping single nucleotide polymorphisms using intact polymerase chain reaction products by electrospray quadrupole mass spectrometry [J].
Walters, JJ ;
Muhammad, W ;
Fox, KF ;
Fox, A ;
Xie, DW ;
Creek, KE ;
Pirisi, L .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (18) :1752-1759
[82]  
WEBER JL, 1989, AM J HUM GENET, V44, P388
[83]   Accurate mass liquid chromatography/mass spectrometry on quadrupole orthogonal acceleration time-of flight mass analyzers using switching between separate sample and reference sprays. 2. Applications using the dual-electrospray ion source [J].
Wolff, JC ;
Eckers, C ;
Sage, AB ;
Giles, K ;
Bateman, R .
ANALYTICAL CHEMISTRY, 2001, 73 (11) :2605-2612
[84]  
Wunschel DS, 1996, RAPID COMMUN MASS SP, V10, P29, DOI 10.1002/(SICI)1097-0231(19960115)10:1<29::AID-RCM430>3.0.CO
[85]  
2-#
[86]   Electrospray ionization Fourier transform ion cyclotron resonance analysis of large polymerase chain reaction products [J].
Wunschel, DS ;
Tolic, LP ;
Feng, BB ;
Smith, RD .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2000, 11 (04) :333-337
[87]   Heterogeneity in Bacillus cereus PCR products detected by ESI-FTICR mass spectrometry [J].
Wunschel, DS ;
Muddiman, DC ;
Fox, KF ;
Fox, A ;
Smith, RD .
ANALYTICAL CHEMISTRY, 1998, 70 (06) :1203-1207