Real-time elastography -: an advanced method of ultrasound:: first results in 108 patients with breast lesions

被引:202
作者
Thomas, A.
Fischer, T.
Frey, H.
Ohlinger, R.
Grunwald, S.
Blohmer, J. -U.
Winzer, K. -J.
Weber, S.
Kristiansen, G.
Ebert, B.
Kuemmel, S.
机构
[1] Charite Univ Med Berlin, Dept Obstet & Gynecol, D-10117 Berlin, Germany
[2] Charite Univ Med Berlin, Dept Radiol, D-10117 Berlin, Germany
[3] Charite Univ Med Berlin, Dept Pathol, D-10117 Berlin, Germany
[4] St Gertrauden Hosp, Dept Senol, Berlin, Germany
[5] Phys Tech Bundesanstalt, Dept Biomed Opt, Berlin, Germany
[6] Hitachi Med Syst, Wiesbaden, Germany
[7] Ernst Moritz Arndt Univ Greifswald, Dept Obstet & Gynecol, Greifswald, Germany
[8] Univ Homburg Saar, Dept Obstet & Gynecol, Homburg, Germany
关键词
breast lesion; real-time elastography; ultrasound;
D O I
10.1002/uog.2823
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives To evaluate whether real-time elastography, a new, non-invasive method for the diagnosis of breast cancer, improves the differentiation and characterization of benign and malignant breast lesions. Methods Real-time elastography was carried out in 108 potential breast tumor patients with cytologically or histologically confirmed focal breast lesions (59 benign, 49 malignant; median age, 53.9 years; range, 16-84 years). Tumor and healthy tissue were differentiated by measurement of elasticity based on the correlation between tissue properties and elasticity modulus. Evaluation was performed using the three-dimensional (31)) finite element method, in which the information is color-coded and superimposed on the B-mode ultrasound image. A second observer evaluated the elastography images, in order to improve the objectivity of the method. The results of B-mode scan and elastography were compared with those of histology and previous sonographic findings. Sensitivities and specificities were calculated, taking histology as the gold standard. Results B-mode ultrasound bad a sensitivity of 91.8% and a speciflcity of 78%, compared with sensitivities of 77.6% and 79.6% and specificities of 91.5% and 84.7%, respectively, for the two observers evaluating elastography. Agreement between B-mode ultrasound and elastography was good, yielding a weighted kappa of 0.67. Conclusions Our initial clinical results suggest that real-time elastography improves the specificity of breast lesion diagnosis and is a promising new approach for the diagnosis of breast cancer. Elastography provides additional information for differentiating malignant BIRADS (breast imaging reporting and data system) category IV lesions. Copyright (c) 2006 ISUOG. Published by John Wiley &Sons, Ltd.
引用
收藏
页码:335 / 340
页数:6
相关论文
共 32 条
[1]   In vivo breast tumor detection using transient elastography [J].
Bercoff, J ;
Chaffai, S ;
Tanter, M ;
Sandrin, L ;
Catheline, S ;
Fink, M ;
Gennisson, JL ;
Meunier, M .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (10) :1387-1396
[2]   A solution to diffraction biases in sonoelasticity: The acoustic impulse technique [J].
Catheline, S ;
Wu, F ;
Fink, M .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1999, 105 (05) :2941-2950
[3]   ELASTOGRAPHY - ELASTICITY IMAGING USING ULTRASOUND WITH APPLICATION TO MUSCLE AND BREAST IN-VIVO [J].
CESPEDES, I ;
OPHIR, J ;
PONNEKANTI, H ;
MAKLAD, N .
ULTRASONIC IMAGING, 1993, 15 (02) :73-88
[4]   The use of unenhanced Doppler sonography in the evaluation of solid breast lesions [J].
del Cura, JL ;
Elizagaray, E ;
Zabala, R ;
Legórburu, A ;
Grande, D .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (06) :1788-1794
[5]  
Ermert H, 2002, Biomed Tech (Berl), V47 Suppl 1 Pt 2, P886, DOI 10.1515/bmte.2002.47.s1b.886
[6]  
ERMERT H, 1999, MED BIOL ENG COMPU 2, V37, P954
[7]  
Frey H, 2003, RADIOLOGE, V43, P850, DOI 10.1007/s00117-003-0943-2
[8]   Elastography of breast lesions: Initial clinical results [J].
Garra, BS ;
Cespedes, EI ;
Ophir, J ;
Spratt, SR ;
Zuurbier, RA ;
Magnant, CM ;
Pennanen, MF .
RADIOLOGY, 1997, 202 (01) :79-86
[9]   Freehand ultrasound elastography of breast lesions:: Clinical results [J].
Hiltawsky, KM ;
Krüger, M ;
Starke, C ;
Heuser, L ;
Ermert, H ;
Jensen, A .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (11) :1461-1469
[10]   BI-RADS for sonography: Positive and negative predictive values of sonographic features [J].
Hong, AS ;
Rosen, EL ;
Soo, MS ;
Baker, JA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (04) :1260-1265