Treatment of a Segmental Nerve Defect in the Rat with Use of Bioabsorbable Synthetic Nerve Conduits: A Comparison of Commercially Available Conduits

被引:110
作者
Shin, Richard H. [1 ]
Friedrich, Patricia F. [1 ]
Crum, Brian A. [2 ]
Bishop, Allen T. [1 ,3 ]
Shin, Alexander Y. [1 ,3 ]
机构
[1] Mayo Clin, Microvasc Res Lab, Rochester, MN 55905 USA
[2] Mayo Clin, Dept Neurol, Rochester, MN 55905 USA
[3] Mayo Clin, Dept Orthoped Surg, Rochester, MN 55905 USA
关键词
PERIPHERAL-NERVE; SCIATIC-NERVE; POLYGLYCOLIC ACID; MUSCLE REINNERVATION; FUNCTIONAL RECOVERY; REFERENCE ELECTRODE; SKELETAL-MUSCLE; MEDIAN NERVE; REPAIR; REGENERATION;
D O I
10.2106/JBJS.H.01301
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The use of biodegradable synthetic nerve conduits for the reconstruction of segmental nerve defects has been extensively reported in both animal and human studies, with a majority of studies evaluating sensory nerve recovery. However, few studies have compared these nerve conduits for functional motor recovery. The purpose of this study was to compare three commercially available, synthetic, bioabsorbable nerve conduits and autograft with respect to compound muscle action potentials, maximum isometric tetanic force, wet muscle weight, and nerve histomorphometry. Methods: Eighty Lewis rats were divided into four groups according to the type of repair of a 10-mm excision of the sciatic nerve: group I had a reversed autograft; group II, a poly-DL-lactide-epsilon-caprolactone conduit; group III, a typed collagen conduit; and group IV, a polyglycolic acid conduit. All results were compared with the contralateral side. At twelve weeks, the rats underwent bilateral measurements of the compound muscle action potentials of the tibialis anterior and flexor digiti quinti brevis muscles, isometric tetanic force and muscle weight of the tibialis anterior, and peroneal nerve histomorphometry. Results: At twelve weeks, no difference in the percentage of recovery between the autograft and the poly-DL-lactide-epsilon-caprolactone conduit was observed with respect to compound muscle action potentials, isometric muscle force, muscle weight, and axon count measurements. The poly-DL-lactide-epsilon-caprolactone and collagen conduits remained structurally stable at twelve weeks, while the polyglycolic acid conduits had completely collapsed. The polyglycolic acid conduit had the poorest results, with a recovery rate of 15% for compound muscle action potentials and 29% for muscle force. Conclusions: The functional outcome in this rat model was similar for the autograft and the poly-DL-lactide-e-caprolactone conduits when they were used to reconstruct a 10-mm sciatic nerve defect. Functional recovery following the use of the polyglycolic acid conduit was the poorest.
引用
收藏
页码:2194 / 2204
页数:11
相关论文
共 45 条
[1]   A COLLAGEN-BASED NERVE GUIDE CONDUIT FOR PERIPHERAL-NERVE REPAIR - AN ELECTROPHYSIOLOGICAL STUDY OF NERVE REGENERATION IN RODENTS AND NONHUMAN-PRIMATES [J].
ARCHIBALD, SJ ;
KRARUP, C ;
SHEFNER, J ;
LI, ST ;
MADISON, RD .
JOURNAL OF COMPARATIVE NEUROLOGY, 1991, 306 (04) :685-696
[2]  
ARCHIBALD SJ, 1995, J NEUROSCI, V15, P4109
[3]   Collagen nerve guides for surgical repair of brachial plexus birth injury [J].
Ashley, William W., Jr. ;
Weatherly, Trisha ;
Park, Tae Sung .
JOURNAL OF NEUROSURGERY, 2006, 105 (06) :452-456
[4]   Improved functional recovery of denervated skeletal muscle after temporary sensory nerve innervation [J].
Bain, JR ;
Veltri, KL ;
Chamberlain, D ;
Fahnestock, M .
NEUROSCIENCE, 2001, 103 (02) :503-510
[5]   Nerve repair by means of tubulization: Literature review and personal clinical experience comparing biological and synthetic conduits for sensory nerve repair [J].
Battiston, B ;
Geuna, S ;
Ferrero, M ;
Tos, P .
MICROSURGERY, 2005, 25 (04) :258-267
[6]   A prospective clinical evaluation of biodegradable neurolac nerve guides for sensory nerve repair in the hand [J].
Bertleff, MJOE ;
Meek, MF ;
Nicolai, JPA .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2005, 30A (03) :513-518
[7]   SELF-EVALUATION OF WALKING-TRACK MEASUREMENT USING A SCIATIC FUNCTION INDEX [J].
BROWN, CJ ;
MACKINNON, SE ;
EVANS, PJ ;
BAIN, JR ;
MAKINO, AP ;
HUNTER, DA ;
HARE, GMT .
MICROSURGERY, 1989, 10 (03) :226-235
[8]   Effect of a low molecular weight heparin molecule, dalteparin, on cellular apoptosis and inflammatory process in an incisional wound-healing model [J].
Civelek, Ali ;
Ak, Koray ;
Kurtkaya, Ozlem ;
Tekeli, Atike ;
Isbir, Selim ;
Nargileci, Erol ;
Arsan, Sinan ;
Sav, Aydin .
SURGERY TODAY, 2007, 37 (05) :406-411
[9]   Comparison of biodegradable conduits within aged rat sciatic nerve defects [J].
Clavijo-Alvarez, Julio A. ;
Nguyen, Vu T. ;
Santiago, Lizzie Y. ;
Doctor, John S. ;
Lee, W. P. Andrew ;
Marra, Kacey G. .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2007, 119 (06) :1839-1851
[10]   Use of tubes in peripheral nerve repair [J].
Dahlin, LB ;
Lundborg, G .
NEUROSURGERY CLINICS OF NORTH AMERICA, 2001, 12 (02) :341-+