Daily concentrations of trace metals in aerosols in Beijing, China, determined by using inductively coupled plasma mass spectrometry equipped with laser ablation analysis, and source identification of aerosols

被引:114
作者
Okuda, T
Kato, J
Mori, J
Tenmoku, M
Suda, Y
Tanaka, S [1 ]
He, KB
Ma, YL
Yang, F
Yu, XC
Duan, FK
Lei, Y
机构
[1] Tsing Hua Univ, Dept Environm Sci & Engn, Beijing 100084, Peoples R China
[2] Keio Univ, Fac Sci & Technol, Dept Appl Chem, Yokohama, Kanagawa 2238522, Japan
关键词
aerosols; Beijing; chemical mass balance (CMB) receptor model; daily concentrations of trace metals; inductively coupled plasma mass spectrometry equipped with laser ablation (LA/ICP-MS); source identification;
D O I
10.1016/j.scitotenv.2004.04.010
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper describes the daily concentrations of trace metals and ionic constituents in the aerosol of Beijing, China from March 2001 to August 2003. Daily PM10 concentrations were also measured from September 2001 to August 2003. The daily average PM,, concentration at Beijing, China from September 2001 to August 2003 was 171 +/- 117 mug m(-3) (n=673), which is 5-fold higher than at Yokohama, Japan. Trace metal concentrations were analyzed by using inductively coupled plasma mass spectrometry equipped with a laser ablation sample introduction (LA/ICPMS), which is a rapid and simultaneous method for multi-element analysis. The daily average metal concentrations in TSP in Beijing from March 2001 to August 2003 were: Al: 3.5+/-2.4 (n=727), Ti: 0.47+/-0.35 (n=720), V:0.013+/-0.010 (n=716), Cr: 0.019+/-0.015 (n=618), Mn: 0.24+/-0.16 (n=730), Fe: 5.5+/-3.9 (n=728), Co: 0.0046+/-0.0055 (n = 629), Ni: 0.022+/-0.024 (n = 680), Cu: 0.11+/-0.11 (n = 660), Zn: 0.77+/-0.60 (n = 726), As: 0.048+/-0.047 (n=731), Se: 0.010+/-0.010 (n=550), Cd: 0.0068+/-0.0082 (n=709), Sb: 0.033+/-0.036 (n=687), and Ph: 0.43+/-0.50 (n = 728) (unit, mug M-3). All the metal concentrations in TSP in Beijing, China were 1.7-21.8 times higher than those in TSP in the center of Tokyo, Japan. Notably, As concentrations in TSP in Beijing were 20-fold higher than those in Tokyo. Source identification of aerosols in Beijing was carried out by using the chemical mass balance (CMB) receptor model, with the daily concentration of metals in the aerosol. The major primary sources of the aerosol of Beijing were considered to be soil dust and coal combustion. Vehicle exhaust contribution tended to increase. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:145 / 158
页数:14
相关论文
共 26 条
[1]  
[Anonymous], 1994, RES ENV SCI
[2]  
*BEIJ STAT BUR, 2003, BEIJ STAT YB 2003
[3]   Spatial variation of mass concentration of roadside suspended particulate matter in metropolitan Hong Kong [J].
Chan, LY ;
Kwok, WS ;
Lee, SC ;
Chan, CY .
ATMOSPHERIC ENVIRONMENT, 2001, 35 (18) :3167-3176
[4]  
Chen LWA, 2002, ATMOS ENVIRON, V36, P4541
[5]  
Draxler R.R., 2003, HYSPLIT
[6]   CHEMICAL ELEMENT BALANCES AND IDENTIFICATION OF AIR-POLLUTION SOURCES [J].
FRIEDLANDER, SK .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1973, 7 (03) :235-240
[7]  
HAYAKARI S, 2001, J JPN SOC ATMOS ENV, V36, P39
[8]   The characteristics of PM2.5 in Beijing, China [J].
He, KB ;
Yang, FM ;
Ma, YL ;
Zhang, Q ;
Yao, XH ;
Chan, CK ;
Cadle, S ;
Chan, T ;
Mulawa, P .
ATMOSPHERIC ENVIRONMENT, 2001, 35 (29) :4959-4970
[9]   VEHICLE-RELATED HYDROCARBON SOURCE COMPOSITIONS FROM AMBIENT DATA - THE GRACE-SAFER METHOD [J].
HENRY, RC ;
LEWIS, CW ;
COLLINS, JF .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1994, 28 (05) :823-832
[10]   Analysis of ambient particle size distributions using unmix and positive matrix factorization [J].
Kim, E ;
Hopke, PK ;
Larson, TV ;
Covert, DS .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2004, 38 (01) :202-209