Ultrasound is a main noninvasive modality for the assessment of the heart function. Wall tracking from ultrasound data is, however, inherently difficult due to weak echoes, clutter, poor signal-to-noise ratio, and signal dropouts. To cope with these artifacts, pretrained shape models can be applied to constrain the tracking. However, existing methods for incorporating subspace shape constraints in myocardial border tracking use only partial information from the model distribution, and do not exploit spatially varying uncertainties from feature tracking. In this paper, we propose a complete fusion formulation in the information space for robust shape tracking, optimally resolving uncertainties from the system dynamics, heteroscedastic measurement noise, and subspace shape model. We also exploit information from the ground truth initialization where this is available. The new framework is applied for tracking of myocardial borders in very noisy echocardiography sequences. Numerous myocardium tracking experiments validate the theory and show the potential of very accurate wall motion measurements. The proposed framework outperforms the traditional shape-space-constrained tracking algorithm by a significant margin. Due to the optimal fusion of different sources of uncertainties, robust performance is observed even for the most challenging cases.
引用
收藏
页码:849 / 860
页数:12
相关论文
共 56 条
[1]   SEMIAUTOMATED BORDER TRACKING OF CINE ECHOCARDIOGRAPHIC VENTRICULAR IMAGES [J].
ADAM, D ;
HAREUVENI, O ;
SIDEMAN, S .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1987, 6 (03) :266-271
[2]   A coarse-to-fine deformable contour optimization framework [J].
Akgul, YS ;
Kambhamettu, C .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 2003, 25 (02) :174-186
[3]  
ALTHOFF K, 2000, P IEEE COMPUTERS CAR, V3653, P29
[4]   Tag surface reconstruction and tracking of myocardial beads from SPAMM-MRI with parametric B-spline surfaces [J].
Amini, AA ;
Chen, Y ;
Elayyadi, M ;
Radeva, P .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (02) :94-103
[5]  
[Anonymous], STAT MODELS APPEARAN
[6]  
[Anonymous], P EUR C COMP VIS
[7]  
Avidan S, 2001, PROC CVPR IEEE, P184
[8]  
BARALDI P, 1986, IEEE T BIOMED ENG BM, V43, P259
[9]   THE EFFECT OF THE COMMON PROCESS NOISE ON THE 2-SENSOR FUSED-TRACK COVARIANCE [J].
BARSHALOM, Y ;
CAMPO, L .
IEEE TRANSACTIONS ON AEROSPACE AND ELECTRONIC SYSTEMS, 1986, 22 (06) :803-805
[10]  
Baumberg A. M., 1994, Proceedings of the 1994 IEEE Workshop on Motion of Non-Rigid and Articulated Objects (Cat. No.94TH0671-8), P194, DOI 10.1109/MNRAO.1994.346236