Evaluation of Several MS/MS Search Algorithms for Analysis of Spectra Derived from Electron Transfer Dissociation Experiments

被引:43
作者
Kandasamy, Kumaran [1 ,2 ,3 ,4 ]
Pandey, Akhilesh [1 ,2 ,3 ]
Molina, Henrik [1 ,2 ,3 ,5 ]
机构
[1] Johns Hopkins Univ, McKusick Nathans Inst Genet Med, Baltimore, MD 21205 USA
[2] Johns Hopkins Univ, Dept Biol Chem, Baltimore, MD 21205 USA
[3] Johns Hopkins Univ, Dept Pathol & Oncol, Baltimore, MD 21205 USA
[4] Int Tech Pk Ltd, Inst Bioinformat, Bangalore 560066, Karnataka, India
[5] Ctr Regulacio Genom, Barcelona 08003, Spain
关键词
TANDEM MASS-SPECTROMETRY; COLLISION-INDUCED DISSOCIATION; SIDE-CHAIN LOSSES; CAPTURE DISSOCIATION; PROTEIN IDENTIFICATION; SITE LOCALIZATION; SEQUENCE-ANALYSIS; PEPTIDES; DATABASE; INFORMATION;
D O I
10.1021/ac9006107
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electron transfer dissociation (ETD) is increasingly becoming popular for high-throughput experiments especially in the identification of the labile post-translational modifications. Most search algorithms that are currently in use for querying MS/MS data against protein databases have been optimized on the basis of matching fragment ions derived from collision induced dissociation of peptides, which are dominated by b and y ions. However, electron transfer dissociation of peptides generates completely different types of fragments: c and z ions. The goal of our study was to test the ability of different search algorithms to handle data from this fragmentation method. We compared four MS/MS search algorithms (OMSSA, Mascot, Spectrum Mill, and X!Tandem) using similar to 170 000 spectra generated from a standard protein mix, as well as from complex proteomic samples which included a large number of phosphopeptides. Our analysis revealed (1) greater differences between algorithms than has been previously reported for CID data, (2) a significant charge state bias resulting in > 60-fold difference in the numbers of matched doubly charged peptides, and (3) identification of 70% more peptides by the best performing algorithm than the algorithm identifying the least number of peptides. Our results indicate that the search engines for analyzing ETD derived MS/MS spectra are still in their early days and that multiple search engines could be used to reduce individual biases of algorithms.
引用
收藏
页码:7170 / 7180
页数:11
相关论文
共 45 条
[1]   SLoMo: Automated Site Localization of Modifications from ETD/ECD Mass Spectra [J].
Bailey, Christopher M. ;
Sweet, Steve M. M. ;
Cunningham, Debbie L. ;
Zeller, Martin ;
Heath, John K. ;
Cooper, Helen J. .
JOURNAL OF PROTEOME RESEARCH, 2009, 8 (04) :1965-1971
[2]   Comparative evaluation of tandem MS search algorithms using a target-decoy search strategy [J].
Balgley, Brian M. ;
Laudeman, Tom ;
Yang, Li ;
Song, Tao ;
Lee, Cheng S. .
MOLECULAR & CELLULAR PROTEOMICS, 2007, 6 (09) :1599-1608
[3]   Large-scale characterization of HeLa cell nuclear phosphoproteins [J].
Beausoleil, SA ;
Jedrychowski, M ;
Schwartz, D ;
Elias, JE ;
Villén, J ;
Li, JX ;
Cohn, MA ;
Cantley, LC ;
Gygi, SP .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2004, 101 (33) :12130-12135
[4]   A probability-based approach for high-throughput protein phosphorylation analysis and site localization [J].
Beausoleil, Sean A. ;
Villen, Judit ;
Gerber, Scott A. ;
Rush, John ;
Gygi, Steven P. .
NATURE BIOTECHNOLOGY, 2006, 24 (10) :1285-1292
[5]   Identification of protein O-GlcNAcylation sites using electron transfer dissociation mass spectrometry on native peptides [J].
Chalkley, Robert J. ;
Thalhammer, Agnes ;
Schoepfer, Ralf ;
Burlingame, A. L. .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2009, 106 (22) :8894-8899
[6]   Evaluation of algorithms for protein identification from sequence databases using mass spectrometry data [J].
Chamrad, DC ;
Körting, G ;
Stühler, K ;
Meyer, HE ;
Klose, J ;
Blüggel, M .
PROTEOMICS, 2004, 4 (03) :619-628
[7]   Analysis of phosphorylation sites on proteins from Saccharomyces cerevisiae by electron transfer dissociation (ETD) mass spectrometry [J].
Chi, An ;
Huttenhower, Curtis ;
Geer, Lewis Y. ;
Coon, Joshua J. ;
Syka, John E. P. ;
Bai, Dina L. ;
Shabanowitz, Jeffrey ;
Burke, Daniel J. ;
Troyanskaya, Olga G. ;
Hunt, Donald F. .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2007, 104 (07) :2193-2198
[8]   Role of accurate mass measurement (±10 ppm) in protein identification strategies employing MS or MS MS and database searching [J].
Clauser, KR ;
Baker, P ;
Burlingame, AL .
ANALYTICAL CHEMISTRY, 1999, 71 (14) :2871-2882
[9]   Characterization of amino acid side chain losses in electron capture dissociation [J].
Cooper, HJ ;
Hudgins, RR ;
Håkansson, K ;
Marshall, AG .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2002, 13 (03) :241-249
[10]   How Much Peptide Sequence Information Is Contained in Ion Trap Tandem Mass Spectra? [J].
Cox, Juergen ;
Hubner, Nina C. ;
Mann, Matthias .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2008, 19 (12) :1813-1820