Amperometric immunosensor based on toluidine blue/nano-Au through electrostatic interaction for determination of carcinoembryonic antigen

被引:95
作者
Li, Xuelian [1 ]
Yuan, Ruo [1 ]
Chai, Yaqin [1 ]
Zhang, Lingyan [1 ]
Zhuo, Ying [1 ]
Zhang, Ying [1 ]
机构
[1] Southwest Univ, Chongqing Key Lab Analyt Chem, Chongqing 400715, Peoples R China
基金
中国国家自然科学基金;
关键词
immunosensor; carcinoembryonic antigen; horseradish peroxidase; toluidine blue; electrostatic interactions;
D O I
10.1016/j.jbiotec.2005.11.023
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
A new current amplified inummosensor for the determination of carcinoembryonic antigen (CEA) was demonstrated in this work. The electrode architecture was fabricated by positively charged toluidine blue (TB) coated on negatively charged polysulfanific acid (PSAA) modified glassy carbon electrode (GCE) surface through electrostatic interactions to form a TB/PSAA film, which provided an interface containing amine groups to assemble gold nanoparticles (nano-Au) for immobilization of carcinoembryonic antibody (anti-CEA) and horseradish peroxidase (HRP) instead of bovine serum albumin (BSA) to block sites against non-specific binding. Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) were employed to characterize the electrochemical properties of the modified processes: The CVs reduction current of the inummosensor charged linearly in two concentration ranges of CEA from 0.5 to 5.0 and 5.0 to 120.0 ng/ml in presence of 0.3 m.M H2O2 in analyte solution, and the detection limit was 0.2 ng/ml at three times background noise. The proposed method is economical, efficient and potentially attractive for clinical immunoassays. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:356 / 366
页数:11
相关论文
共 40 条
[1]  
Andrey L.G., 1998, BIOSENS BIOELECTRON, V13, P113
[2]   REUSABLE FIBER OPTIC IMMUNOSENSOR FOR RAPID DETECTION OF IMAZETHAPYR HERBICIDE [J].
ANIS, NA ;
ELDEFRAWI, ME ;
WONG, RB .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1993, 41 (05) :843-848
[3]   CARCINOEMBRYONIC ANTIGEN, A HUMAN-TUMOR MARKER, FUNCTIONS AS AN INTERCELLULAR-ADHESION MOLECULE [J].
BENCHIMOL, S ;
FUKS, A ;
JOTHY, S ;
BEAUCHEMIN, N ;
SHIROTA, K ;
STANNERS, CP .
CELL, 1989, 57 (02) :327-334
[4]   REGENERABLE FIBER-OPTIC-BASED IMMUNOSENSOR [J].
BRIGHT, FV ;
BETTS, TA ;
LITWILER, KS .
ANALYTICAL CHEMISTRY, 1990, 62 (10) :1065-1069
[5]   Hydrogen peroxide biosensor based on sol-gel-derived glasses doped with Eastman AQ polymer [J].
Chen, X ;
Zhang, JZ ;
Wang, BQ ;
Cheng, GJ ;
Dong, SJ .
ANALYTICA CHIMICA ACTA, 2001, 434 (02) :255-260
[6]   Carbon electrodes modified with ruthenium metallodendrimer multilayers for the mediated oxidation of methionine and insulin at physiological pH [J].
Cheng, L ;
Pacey, GE ;
Cox, JA .
ANALYTICAL CHEMISTRY, 2001, 73 (22) :5607-5610
[7]   SEMICONDUCTOR NANOCRYSTALS COVALENTLY BOUND TO METAL-SURFACES WITH SELF-ASSEMBLED MONOLAYERS [J].
COLVIN, VL ;
GOLDSTEIN, AN ;
ALIVISATOS, AP .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1992, 114 (13) :5221-5230
[8]   Layer-by-layer self-assembled chitosan/poly(thiophene-3-acetic acid) and organophosphorus hydrolase multilayers [J].
Constantine, CA ;
Mello, SV ;
Dupont, A ;
Cao, XH ;
Santos, D ;
Oliveira, ON ;
Strixino, FT ;
Pereira, EC ;
Cheng, TC ;
Defrank, JJ ;
Leblanc, RM .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2003, 125 (07) :1805-1809
[9]   Reagentless amperometric immunosensors based on direct electrochemistry of horseradish peroxidase for determination of carcinoma antigen-125 [J].
Dai, Z ;
Yan, F ;
Chen, J ;
Ju, HX .
ANALYTICAL CHEMISTRY, 2003, 75 (20) :5429-5434
[10]  
Downard AJ, 1999, ELECTROANAL, V11, P418, DOI 10.1002/(SICI)1521-4109(199905)11:6<418::AID-ELAN418>3.3.CO