Age related compliance of the lamina cribrosa in human eyes

被引:188
作者
Albon, J
Purslow, PP
Karwatowski, WSS
Easty, DL
机构
[1] Univ Wales Coll Cardiff, Cell & Mol Biol Unit, Dept Optometry & Vis Sci, Cardiff CF1 3XF, S Glam, Wales
[2] Royal Vet & Agr Univ, Dept Dairy & Food Sci, DK-1870 Frederiksberg, Denmark
[3] Leicester Royal Infirm, Dept Ophthalmol, Leicester, Leics, England
[4] Bristol Eye Hosp, Dept Ophthalmol, Bristol, Avon, England
关键词
D O I
10.1136/bjo.84.3.318
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aims-To investigate changes in the mechanical compliance of ex vivo human lamina cribrosa with age. Methods-A laser scanning confocal microscope was used to image the surface of the fluorescently labelled lamina cribrosa in cadaver eyes. A method was developed to determine changes in the volume and strain of the lamina cribrosa created by increases in pressure. The ability of the lamina cribrosa to reverse its deformation on removal of pressure was also measured. Results-Volume and strain measurements both demonstrated that the lamina cribrosa increased in stiffness with age and the level of pressure applied. The ability of the lamina cribrosa to regain its original shape and size on removal of pressure appeared to decrease with age, demonstrating an age related decrease in resilience of the lamina cribrosa. Conclusions-The mechanical compliance of the human lamina cribrosa decreased with age. Misalignment of compliant cribriform plates in a young eye may exert a lesser stress on nerve axons, than that exerted by the rigid plates of an elderly lamina cribrosa. The resilience of the lamina cribrosa also decreased with age, suggesting an increased susceptibility to plastic flow and permanent deformation. Such changes may be of importance in the explanation of age related optic neuropathy in primary open angle glaucoma.
引用
收藏
页码:318 / 323
页数:6
相关论文
共 32 条
  • [1] CHANGES IN THE COLLAGENOUS MATRIX OF THE AGING HUMAN LAMINA-CRIBROSA
    ALBON, J
    KARWATOWSKI, WSS
    AVERY, N
    EASTY, DL
    DUANCE, VC
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 1995, 79 (04) : 368 - 375
  • [2] Albon J., 1995, THESIS U BRISTOL BRI
  • [3] Azuara-Blanco A, 1997, Curr Opin Ophthalmol, V8, P50, DOI 10.1097/00055735-199704000-00009
  • [4] Bellezza A. J., 1998, IOVS, V39, pS27
  • [5] Measurement of optic disc compliance by digitized image analysis in the normal monkey eye
    Burgoyne, CF
    Quigley, HA
    Thompson, HW
    Vitale, S
    Varma, R
    [J]. OPHTHALMOLOGY, 1995, 102 (12) : 1790 - 1799
  • [6] Early changes in optic disc compliance and surface position in experimental glaucoma
    Burgoyne, CF
    Quigley, HA
    Thompson, HW
    Vitale, S
    Varma, R
    [J]. OPHTHALMOLOGY, 1995, 102 (12) : 1800 - 1809
  • [7] BURGOYNE CF, 1994, ARCH OPHTHALMOL-CHIC, V112, P1261
  • [8] BURRINGTON RS, 1965, HDB MATH TABLES FORM
  • [9] COLEMAN AL, 1991, OPHTHALMOLOGY, V98, P35
  • [10] EMERY JM, 1981, T AM ACAD OPHTHALMOL, V78, pOP290