Generalized Least-Squares CT Reconstruction with Detector Blur and Correlated Noise Models

被引:9
作者
Stayman, J. Webster [1 ]
Zbijewski, Wojciech [1 ]
Tilley, Steven, II [1 ]
Siewerdsen, Jeffrey [1 ]
机构
[1] Johns Hopkins Univ, Dept Biomed Eng, Baltimore, MD 21205 USA
来源
MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING | 2014年 / 9033卷
关键词
Sinogram restoration; model-based iterative reconstruction; projection deblurring; correlated noise; crosstalk; high-resolution cone-beam computed tomography; ITERATIVE RECONSTRUCTION; IMAGE-RECONSTRUCTION; COMPUTED-TOMOGRAPHY; PROJECTION; QUALITY;
D O I
10.1117/12.2043067
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The success and improved dose utilization of statistical reconstruction methods arises, in part, from their ability to incorporate sophisticated models of the physics of the measurement process and noise. Despite the great promise of statistical methods, typical measurement models ignore blurring effects, and nearly all current approaches make the presumption of independent measurements disregarding noise correlations and a potential avenue for improved image quality. In some imaging systems, such as flat-panel-based cone-beam CT, such correlations and blurs can be a dominant factor in limiting the maximum achievable spatial resolution and noise performance. In this work, we propose a novel regularized generalized least-squares reconstruction method that includes models for both system blur and correlated noise in the projection data. We demonstrate, in simulation studies, that this approach can break through the traditional spatial resolution limits of methods that do not model these physical effects. Moreover, in comparison to other approaches that attempt deblurring without a correlation model, superior noise-resolution trade-offs can be found with the proposed approach.
引用
收藏
页数:6
相关论文
共 10 条
[1]   Statistical image reconstruction from correlated data with applications to PET [J].
Alessio, Adam ;
Sauer, Ken ;
Kinahan, Paul .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (20) :6133-6150
[2]   Distance-driven projection and backprojection in three dimensions [J].
De Man, B ;
Basu, S .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (11) :2463-2475
[3]   Incorporation of system resolution compensation (RC) in the ordered-subset transmission (OSTR) algorithm for transmission imaging in SPECT [J].
Feng, Bing ;
Fessler, Jeffrey A. ;
King, Michael A. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (07) :941-949
[4]   Penalized-likelihood sinogram restoration for computed tomography [J].
La Riviere, Patrick J. ;
Bian, Junguo ;
Vargas, Phillip A. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (08) :1022-1036
[5]   3D Forward and Back-Projection for X-Ray CT Using Separable Footprints [J].
Long, Yong ;
Fessler, Jeffrey A. ;
Balter, James M. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (11) :1839-1850
[6]   Modelling the physics in the iterative reconstruction for transmission computed tomography [J].
Nuyts, Johan ;
De Man, Bruno ;
Fessler, Jeffrey A. ;
Zbijewski, Wojciech ;
Beekman, Freek J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (12) :R63-R96
[7]   A three-dimensional statistical approach to improved image quality for multislice helical CT [J].
Thibault, Jean-Baptiste ;
Sauer, Ken D. ;
Bouman, Charles A. ;
Hsieh, Jiang .
MEDICAL PHYSICS, 2007, 34 (11) :4526-4544
[8]  
Whiting B, 2004, MED PHYS, V31, P1744
[9]   Adaptive Statistical Iterative Reconstruction and Veo: Assessment of Image Quality and Diagnostic Performance in CT Colonography at Various Radiation Doses [J].
Yoon, Min A. ;
Kim, Se Hyung ;
Lee, Jeong Min ;
Woo, Hyoun Sik ;
Lee, Eun Sun ;
Ahn, Se Jin ;
Han, Joon Koo .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2012, 36 (05) :596-601
[10]   Maximum-likelihood transmission image reconstruction for overlapping transmission beams [J].
Yu, DF ;
Fessler, JA ;
Ficaro, EP .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (11) :1094-1105