Targeted Metabolomics Identifies Reliable and Stable Metabolites in Human Serum and Plasma Samples

被引:189
作者
Breier, Michaela [1 ,2 ,3 ,4 ,5 ]
Wahl, Simone [1 ,2 ,3 ]
Prehn, Cornelia [6 ]
Fugmann, Marina [3 ,4 ,5 ,7 ]
Ferrari, Uta [3 ,4 ,5 ,7 ]
Weise, Michaela [3 ,4 ,5 ,7 ]
Banning, Friederike [3 ,4 ,5 ,7 ]
Seissler, Jochen [4 ,5 ,7 ]
Grallert, Harald [1 ,2 ,3 ,4 ,5 ]
Adamski, Jerzy [3 ,6 ,8 ]
Lechner, Andreas [3 ,4 ,5 ,7 ]
机构
[1] German Res Ctr Environm Hlth, Helmholtz Zentrum Muenchen, Res Unit Mol Epidemiol, Neuherberg, Germany
[2] German Res Ctr Environm Hlth, Helmholtz Zentrum Muenchen, Inst Epidemiol 2, Neuherberg, Germany
[3] German Ctr Diabet Res, Neuherberg, Germany
[4] Univ Munich, Clin Cooperat Grp Subclassificat Type Diabet 2, Munich, Germany
[5] Helmholtz Zentrum Muenchen, Munich, Germany
[6] German Res Ctr Environm Hlth, Helmholtz Zentrum Muenchen, Genome Anal Ctr, Inst Expt Genet, Neuherberg, Germany
[7] Klinikum Univ Munchen, Diabet Res Grp, Med Klin & Poliklin 4, Munich, Germany
[8] Tech Univ Munich, Chair Expt Genet, Freising Weihenstephan, Germany
关键词
WHOLE-BLOOD; STABILITY; SEPARATION; ACID;
D O I
10.1371/journal.pone.0089728
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
070301 [无机化学]; 070403 [天体物理学]; 070507 [自然资源与国土空间规划学]; 090105 [作物生产系统与生态工程];
摘要
Background: Information regarding the variability of metabolite levels over time in an individual is required to estimate the reproducibility of metabolite measurements. In intervention studies, it is critical to appropriately judge changes that are elicited by any kind of intervention. The pre-analytic phase (collection, transport and sample processing) is a particularly important component of data quality in multi-center studies. Methods: Reliability of metabolites (within-and between-person variance, intraclass correlation coefficient) and stability (shipment simulation at different temperatures, use of gel-barrier collection tubes, freeze-thaw cycles) were analyzed in fasting serum and plasma samples of 22 healthy human subjects using a targeted LC-MS approach. Results: Reliability of metabolite measurements was higher in serum compared to plasma samples and was good in most saturated short-and medium-chain acylcarnitines, amino acids, biogenic amines, glycerophospholipids, sphingolipids and hexose. The majority of metabolites were stable for 24 h on cool packs and at room temperature in non-centrifuged tubes. Plasma and serum metabolite stability showed good coherence. Serum metabolite concentrations were mostly unaffected by tube type and one or two freeze-thaw cycles. Conclusion: A single time point measurement is assumed to be sufficient for a targeted metabolomics analysis of most metabolites. For shipment, samples should ideally be separated and frozen immediately after collection, as some amino acids and biogenic amines become unstable within 3 h on cool packs. Serum gel-barrier tubes can be used safely for this process as they have no effect on concentration in most metabolites. Shipment of non-centrifuged samples on cool packs is a cost-efficient alternative for most metabolites.
引用
收藏
页数:11
相关论文
共 32 条
[1]
Questionnaire-based self-reported nutrition habits associate with serum metabolism as revealed by quantitative targeted metabolomics [J].
Altmaier, Elisabeth ;
Kastenmueller, Gabi ;
Roemisch-Margl, Werner ;
Thorand, Barbara ;
Weinberger, Klaus M. ;
Illig, Thomas ;
Adamski, Jerzy ;
Doering, Angela ;
Suhre, Karsten .
EUROPEAN JOURNAL OF EPIDEMIOLOGY, 2011, 26 (02) :145-156
[2]
[Anonymous], R LANG ENV STAT COMP
[3]
[Anonymous], METABOLOMICS
[4]
Roles of ceramide and sphingolipids in pancreatic β-cell function and dysfunction [J].
Boslem, Ebru ;
Meikle, Peter J. ;
Biden, Trevor J. .
ISLETS, 2012, 4 (03) :177-187
[5]
Stabilization of Glucose in Blood Samples: Why It Matters [J].
Bruns, David E. ;
Knowler, William C. .
CLINICAL CHEMISTRY, 2009, 55 (05) :850-852
[6]
Phospholipase A2 Biochemistry [J].
Burke, John E. ;
Dennis, Edward A. .
CARDIOVASCULAR DRUGS AND THERAPY, 2009, 23 (01) :49-59
[7]
The creatine-creatinine equilibrium. The apparent dissociation constants of creatine and creatinine. [J].
Cannan, RK ;
Shore, A .
BIOCHEMICAL JOURNAL, 1928, 22 (04) :920-929
[8]
Carpenter J, 2000, STAT MED, V19, P1141, DOI 10.1002/(SICI)1097-0258(20000515)19:9<1141::AID-SIM479>3.0.CO
[9]
2-F
[10]
Stability of plasma analytes after delayed separation of whole blood: implications for epidemiological studies [J].
Clark, S ;
Youngman, LD ;
Palmer, A ;
Parish, S ;
Peto, R ;
Collins, R .
INTERNATIONAL JOURNAL OF EPIDEMIOLOGY, 2003, 32 (01) :125-130