A comparison of Tactaid II plus and Tactaid 7 use by adults with a profound hearing impairment

被引:13
作者
Galvin, KL
Mavrias, G
Moore, A
Cowan, RSC
Blamey, PJ
Clark, GM
机构
[1] CRC Cochlear Implant Speech & Hearing Res, Melbourne, Vic, Australia
[2] Bion Ear Inst, Melbourne, Vic, Australia
[3] Australian Hearing Serv, Sydney, NSW, Australia
[4] Univ Melbourne, Melbourne, Vic, Australia
关键词
D O I
10.1097/00003446-199912000-00003
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Objective: To evaluate and compare use of the Tactaid II+ and the Tactaid 7, in terms of speech perception, by adults with a hearing impairment. Design: Eight adults used one device daily for approximately 10 wk and attended seven training sessions. Performance was measured with tests of phonetic contrast perception, closed-set vowel and consonant identification, word and phoneme recognition in monosyllabic word lists, word recognition in sentences and speechtracking rate. A questionnaire was also administered. The protocol was repeated with the alternative device. Results: With each device, the group discriminated most phonetic contrasts at better-than-chance levels and demonstrated somewhat enhanced visual or auditory-visual perception when measured in terms of vowel identification, monosyllabic word recognition and speechtracking rate. An increase in speechtracking rate was also demonstrated for some individuals. Subjects generally reported little subjective improvement in speech perception and production, but were satisfied with the physical attributes of each device. Five of six subjects preferred the Tactaid 7. Conclusions: The Tactaid II+ and the Tactaid 7 provided suprasegmental and segmental information, enabling the group to discriminate phonetic contrasts and improve their perception of some speech materials. No consistent advantage was found for either device, thought most subjects preferred the Tactaid 7. Alternatives likely to provide a greater benefit to communication should be considered before a Tactaid fitting.
引用
收藏
页码:471 / 482
页数:12
相关论文
共 26 条
[1]  
*AM NAT STAND I, 1989, SPEC AUD STAND S3 6
[2]   METHOD FOR TRAINING AND EVALUATING RECEPTION OF ONGOING SPEECH [J].
DEFILIPPO, CL ;
SCOTT, BL .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1978, 63 (04) :1186-1192
[3]   FACTORS IN THE DEVELOPMENT OF A TRAINING-PROGRAM FOR USE WITH TACTILE DEVICES [J].
GALVIN, KL ;
COWAN, RSC ;
SARANT, JZ ;
BLAMEY, PJ ;
CLARK, GM .
EAR AND HEARING, 1993, 14 (02) :118-127
[4]  
GLEITZMAN M, 1991, MISERY GUTS
[5]  
Kessler D K, 1997, Scand Audiol Suppl, V47, P45
[6]  
LEVITT H, 1997, PRACTICAL HEARING AI, V1, pR11
[7]  
Levitt H., 1980, SENSORY AIDS HEARING
[8]  
LYNCH MP, 1988, J SPEECH HEAR RES, V32, P331
[9]  
MAGNER ME, 1972, SPEECH INTELLIGIBILT
[10]   Control of hearing-aid saturated sound pressure level by frequency-shaped output compression limiting [J].
McDermott, HJ ;
Dean, MR ;
Dillon, H .
SCANDINAVIAN AUDIOLOGY, 1999, 28 (01) :27-38