Consciousness monitoring in ventilated patients: bispectral EEG monitors arousal not delirium

被引:65
作者
Ely, EW [1 ]
Truman, B
Manzi, DJ
Sigl, JC
Shintani, A
Bernard, GR
机构
[1] Vanderbilt Univ, Sch Med, Ctr Geriatr Res Educ & Clin, Tennessee Valley Vet Affairs Healthcare Syst, Nashville, TN 37212 USA
[2] Vanderbilt Univ, Sch Med, Dept Internal Med, Div Allergy Pulm Crit Care Med,Ctr Hlth Serv Res, Nashville, TN 37212 USA
[3] Aspect Med Syst, Nashville, TN USA
关键词
bispectral index; BIS; electroencephalogram; delirium; encephalopathy; aging;
D O I
10.1007/s00134-004-2298-1
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective. Bispectral index (BIS) is being evaluated as a monitor of consciousness, yet it is unclear what components of consciousness (i.e., arousal vs. content of consciousness) the BIS measures. This study compared BIS levels to well-validated clinical measures of arousal and the presence or absence of delirium. Design. A prospective, blinded, observational cohort study. Patients. 124 mechanically ventilated, adult, medical ICU patients. Measurements and results. Using BIS 3.4 and BIS-XP 4.0 algorithms, BIS values were calculated immediately prior to clinical assessments. The clinical assessments included the Richmond Agitation-Sedation Scale (RASS) and presence or absence of delirium using the Confusion Assessment Method for the ICU. A total of 484 assessments were collected among 124 patients. BIS-XP values demonstrated greater correlation with RASS than BIS 3.4 (R-2=0.36 vs. 0.20), although considerable overlap of BIS-XP scores remained across RASS levels. Median BIS-XP values for delirious and nondelirious observations were 74 and 96, respectively, while BIS 3.4 values were 91 and 96, respectively. However, neither BIS 3.4 nor BIS-XP were significantly associated with delirium after controlling for RASS value. Conclusions. In comparison with clinical measures of arousal in mechanically ventilated patients, BIS-XP algorithm demonstrated stronger correlation with RASS levels than did BIS 3.4, yet marked overlap across different levels of arousal persist using both algorithms. After controlling for level of arousal, neither BIS-XP nor BIS 3.4 algorithms distinguished between the presence and absence of delirium.
引用
收藏
页码:1537 / 1543
页数:7
相关论文
共 39 条
[1]   Introduction of sedative, analgesic, and neuromuscular blocking agent guidelines in a medical intensive care unit: Physician and nurse adherence [J].
Bair, N ;
Bobek, MB ;
Hoffman-Hogg, L ;
Mion, LC ;
Slomka, J ;
Arroliga, AC .
CRITICAL CARE MEDICINE, 2000, 28 (03) :707-713
[2]   The correlation of the bispectral index monitor with clinical sedation scores during mechanical ventilation in the pediatric intensive care unit [J].
Berkenbosch, JW ;
Fichter, CR ;
Tobias, JD .
ANESTHESIA AND ANALGESIA, 2002, 94 (03) :506-511
[3]   A comparison of spectral edge, delta power, and bispectral index as EEG measures of alfentanil, propofol, and midazolam drug effect [J].
Billard, V ;
Gambus, PL ;
Chamoun, N ;
Stanski, DR ;
Shafer, SL .
CLINICAL PHARMACOLOGY & THERAPEUTICS, 1997, 61 (01) :45-58
[4]  
Campbell M L, 1998, Am J Crit Care, V7, P85
[5]   Use of continuous bispectral EEG monitoring to assess depth of sedation in ICU patients [J].
De Deyne, C ;
Struys, M ;
Decruyenaere, J ;
Creupelandt, J ;
Hoste, E ;
Colardyn, F .
INTENSIVE CARE MEDICINE, 1998, 24 (12) :1294-1298
[6]   Using and understanding sedation scoring systems: a systematic review [J].
De Jonghe, B ;
Cook, D ;
Appere-De-Vecchi, C ;
Guyatt, G ;
Meade, M ;
Outin, H .
INTENSIVE CARE MEDICINE, 2000, 26 (03) :275-285
[7]   Administration of sedatives and level of sedation: Comparative evaluation via the Sedation-Agitation Scale and the Bispectral Index [J].
de Wit, M ;
Epstein, SK .
AMERICAN JOURNAL OF CRITICAL CARE, 2003, 12 (04) :343-348
[8]   Monitoring sedation status over time in ICU patients - Reliability and validity of the Richmond Agitation-Sedation Scale (RASS) [J].
Ely, EW ;
Truman, B ;
Shintani, A ;
Thomason, JWW ;
Wheeler, AP ;
Gordon, S ;
Francis, J ;
Speroff, T ;
Gautam, S ;
Margolin, R ;
Sessler, CN ;
Dittus, RS ;
Bernard, GR .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2003, 289 (22) :2983-2991
[9]   Delirium in mechanically ventilated patients - Validity and reliability of the Confusion Assessment Method for the intensive care unit (CAM-ICU) [J].
Ely, EW ;
Inouye, SK ;
Bernard, GR ;
Gordon, S ;
Francis, J ;
May, L ;
Truman, B ;
Speroff, T ;
Gautam, S ;
Margolin, R ;
Hart, RP ;
Dittus, R .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2001, 286 (21) :2703-2710
[10]   Evaluation of delirium in critically ill patients: Validation of the Confusion Assessment Method for the Intensive Care Unit (CAM-ICU) [J].
Ely, EW ;
Margolin, R ;
Francis, J ;
May, L ;
Truman, B ;
Dittus, R ;
Speroff, T ;
Gautam, S ;
Bernard, GR ;
Inouye, SK .
CRITICAL CARE MEDICINE, 2001, 29 (07) :1370-1379