Affordable CD4+-T-Cell counting by flow cytometry:: CD45 Gating for volumetric analysis

被引:47
作者
Janossy, G
Jani, IV
Bradley, NJ
Bikoue, A
Pitfield, T
Glencross, DK
机构
[1] UCL Royal Free & Univ Coll Med Sch, Dept Immunol & Mol Pathol, London NW3 2PF, England
[2] Univ Witwatersrand, Fac Hlth Sci, Dept Mol Med & Hematol, Johannesburg, South Africa
关键词
D O I
10.1128/CDLI.9.5.1085-1094.2002
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
The flow cytometers that are currently supported by industry provide accurate CD4(+)-T-cell counts for monitoring human immunodeficiency virus disease but remain unaffordable for routine service work under resource-poor conditions. We therefore combined volumetric flow cytometry (measuring absolute lymphocyte counts in unit volumes of blood) and simpler protocols with generic monoclonal antibodies (MAbs) to increase cost efficiency. Volumetric absolute counts were generated using CD45/CD4 and CD45/CD8 MAb combinations in two parallel tubes. The percentage values for the various subsets were also determined within the leukocyte and lymphocyte populations utilizing a fully automated protocol. The levels of agreement between the newly developed method and the present industry standards, including both volumetric and bead-based systems using a full MAb panel for subset analysis, were tested by Bland-Altman analyses. The limits of agreement for CD4 counts generated by the volumetric methods using either CD45/CD4 (in a single tube) or the full Trio MAb panel (in three tubes) on the CytoronAbsolute flow cytometer were between -29 and +46 cells/mm(3) with very little bias for CD4 counts (in favor of the Trio method: +8 CD4(+) lymphocytes/mm(3); 0.38% of lymphocytes). The limits of agreement for absolute CD4 counts yielded by the volumetric CD45/CD4 method and the bead-based method were between - 118 and + 98 Cells/mm(3), again with a negligible bias (- 10 CD4+ lymphocytes/mm(3)). In the volumetric method using CD45/CD8, the strongly CD8(+) cells were gated and the levels of agreement with the full Trio showed a minor bias (in favor of the Trio; +40 CD8(+) cells/mm(3); 5.2% of lymphocytes) without a significant influence on CD4/CD8 ratios. One trained flow cytometrist was able to process 300 to 400 stained tubes per day. This workload extrapolates to a throughput of >30,000 samples per year if both CD45/CD4 and CD45/CD8 stainings are performed for each patient or a throughput of >60,000 samples if only CD45/CD4 counts are tested in a single tube. Thus, on the basis of the high efficiency and excellent agreement with the present industry standards, volumetric flow cytometers with automated gating protocols and autobiosamplers, complemented by generic CD45, CD4, and CD8 MAbs used in two-color immunofluorescence, represent the most suitable arrangements for large regional laboratories in resource-poor settings.
引用
收藏
页码:1085 / 1094
页数:10
相关论文
共 37 条
[1]  
Barnett D, 1996, CYTOMETRY, V26, P216, DOI 10.1002/(SICI)1097-0320(19960915)26:3<216::AID-CYTO6>3.0.CO
[2]  
2-C
[3]  
BARNETT D, 1998, CYTOMETRY, V38, P88
[4]   A PARALLEL EVALUATION OF 4 AUTOMATED HEMATOLOGY ANALYZERS [J].
BENTLEY, SA ;
JOHNSON, A ;
BISHOP, CA .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1993, 100 (06) :626-632
[5]   Selection of lymphocyte gating protocol has an impact on the level of reliability of T-cell subsets in aging specimens [J].
Bergeron, M ;
Nicholson, JKA ;
Phaneuf, S ;
Ding, T ;
Soucy, N ;
Badley, AD ;
Foss, NCH ;
Mandy, F .
CYTOMETRY, 2002, 50 (02) :53-61
[6]  
Bikoue A, 1996, CYTOMETRY, V26, P137, DOI 10.1002/(SICI)1097-0320(19960615)26:2<137::AID-CYTO7>3.0.CO
[7]  
2-D
[8]   Stabilised cellular immuno-fluorescence assay: CD45 expression as a calibration standard for human leukocytes [J].
Bikoue, A ;
Janossy, G ;
Barnett, D .
JOURNAL OF IMMUNOLOGICAL METHODS, 2002, 266 (1-2) :19-32
[9]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[10]  
BOFILL M, 1992, CLIN EXP IMMUNOL, V88, P243, DOI 10.1111/j.1365-2249.1992.tb03068.x