Volume estimation from multiplanar 2D ultrasound images using a remote electromagnetic position and orientation sensor

被引:53
作者
Hughes, SW
DArcy, TJ
Maxwell, DJ
Chiu, W
Milner, A
Saunders, JE
Sheppard, RJ
机构
[1] GUYS & ST THOMAS HOSP TRUST,DEPT OBSTET & GYNAECOL,LONDON SE1 7EH,ENGLAND
[2] GUYS & ST THOMAS HOSP TRUST,DEPT PAEDIAT,LONDON SE1 7EH,ENGLAND
[3] UNIV LONDON KINGS COLL,DEPT PHYS,LONDON WC2R 2LS,ENGLAND
关键词
three dimensional ultrasound; multiplanar image registration; volume measurement;
D O I
10.1016/0301-5629(96)00022-1
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A system is described for calculating volume from a sequence of multiplanar 2D ultrasound images. Ultrasound images are captured using a video digitising card (Hauppauge Win/TV card) installed in a personal computer, and regions of interest transformed into 3D space using position and orientation data obtained from an electromagnetic device (Polhemus, Fastrak). The accuracy of the system was assessed by scanning 10 water filled balloons (13-141 mt), 10 kidneys (147-200 mt) and 16 fetal livers (8-37 mt) in water using an Acuson 128XP/10 (5 MHz curvilinear probe). Volume was calculated using the ellipsoid, planimetry, tetrahedral and ray tracing methods and compared with the actual volume measured by weighing (balloons) and water displacement (kidneys and livers). The mean percentage error for the ray tracing method was 0.9 +/- 2.4%, 2.7 +/- 2.3%, 6.6 +/- 5.4% for balloons, kidneys and livers, respectively. So far the system has been used clinically to scan fetal livers and lungs, neonate brain ventricles and adult prostate glands.
引用
收藏
页码:561 / 572
页数:12
相关论文
共 44 条
[1]   ROENTGENOGRAPHIC MEASUREMENT OF SKULL SIZE IN CHILDREN [J].
AUSTIN, JHM ;
GOODING, CA .
RADIOLOGY, 1971, 99 (03) :641-&
[2]  
BAMBER J C, 1979, Ultrasound in Medicine and Biology, V5, P149, DOI 10.1016/0301-5629(79)90083-8
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   WORK IN PROGRESS - COMMON CAROTID-ARTERY CONTOURS RECONSTRUCTED IN 3 DIMENSIONS FROM PARALLEL ULTRASONIC IMAGES [J].
BLANKENHORN, DH ;
CHIN, HP ;
STRIKWERDA, S ;
BAMBERGER, J ;
HESTENES, JD .
RADIOLOGY, 1983, 148 (02) :533-537
[5]  
BRINKLEY J F, 1978, Ultrasound in Medicine and Biology, V4, P317, DOI 10.1016/0301-5629(78)90020-0
[6]   AN ALGORITHM FOR VOLUME ESTIMATION BASED ON POLYHEDRAL APPROXIMATION [J].
COOK, LT ;
COOK, PN ;
LEE, KR ;
BATNITZKY, S ;
WONG, BYS ;
FRITZ, SL ;
OPHIR, J ;
DWYER, SJ ;
BIGONGIARI, LR ;
TEMPLETON, AW .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1980, 27 (09) :493-500
[7]  
Cooke J.M., 1992, Presence Teleoperators Virtual Environments, V1, P404, DOI DOI 10.1162/PRES.1992.1.4.404
[8]   THE USE OF BIPLANE ANGIOCARDIOGRAPHY FOR THE MEASUREMENT OF LEFT VENTRICULAR VOLUME IN MAN [J].
DODGE, HT ;
SANDLER, H ;
BALLEW, DW ;
LORD, JD .
AMERICAN HEART JOURNAL, 1960, 60 (05) :762-776
[9]   ACCURATE VOLUME DETERMINATION IN THE ISOLATED EJECTING CANINE LEFT-VENTRICLE BY 2-DIMENSIONAL ECHOCARDIOGRAPHY [J].
EATON, LW ;
MAUGHAN, WL ;
SHOUKAS, AA ;
WEISS, JL .
CIRCULATION, 1979, 60 (02) :320-326
[10]   CHARACTERIZATION OF A SAPHENOUS-VEIN GRAFT ANEURYSM BY INTRAVASCULAR ULTRASOUND AND COMPUTERIZED 3-DIMENSIONAL RECONSTRUCTION [J].
ENNIS, BM ;
ZIENTEK, DM ;
RUGGIE, NT ;
BILLHARDT, RA ;
KLEIN, LW .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1993, 28 (04) :328-331