Fast automatic delineation of cardiac volume of interest in MSCT images

被引:8
作者
Lorenz, C [1 ]
Lessick, J [1 ]
Lavi, G [1 ]
Bülow, T [1 ]
Renisch, S [1 ]
机构
[1] Philips Res Labs, D-22335 Hamburg, Germany
来源
MEDICAL IMAGING 2004: IMAGE PROCESSING, PTS 1-3 | 2004年 / 5370卷
关键词
medical image processing; multi-slice CT; cardiac imaging; cardiac volume of interest; active contour; Fourier contour;
D O I
10.1117/12.533463
中图分类号
TB8 [摄影技术];
学科分类号
0804 [仪器科学与技术];
摘要
Computed Tomography Angiography (CTA) is an emerging modality for assessing cardiac anatomy. The delineation of the cardiac volume of interest (VOI) is a pre-processing step for subsequent visualization or image processing. It serves the suppression of anatomic structures being not in the primary focus of the cardiac application, such as sternum, ribs, spinal column, descending aorta and pulmonary vasculature. These structures obliterate standard visualizations such as direct volume renderings or maximum intensity projections. In addition, outcome and performance of post-processing steps such as ventricle suppression, coronary artery segmentation or the detection of short and long axes of the heart can be improved. The structures being part of the cardiac VOI (coronary arteries and veins, myocardium, ventricles and atria) differ tremendously in appearance. In addition, there is no clear image feature associated with the contour (or better cut-surface) distinguishing between cardiac VOI and surrounding tissue making the automatic delineation of the cardiac VOI a difficult task. The presented approach locates in a first step chest wall and descending aorta in all image slices giving a rough estimate of the location of the heart. In a second step, a Fourier based active contour approach delineates slice-wise the border of the cardiac VOI. The algorithm has been evaluated on 41 multi-slice CT data-sets including cases with coronary stents and venous and arterial bypasses. The typical processing time amounts to 5-10s on a 1GHz P3 PC.
引用
收藏
页码:456 / 466
页数:11
相关论文
共 7 条
[1]
AN ALGORITHM FOR MACHINE CALCULATION OF COMPLEX FOURIER SERIES [J].
COOLEY, JW ;
TUKEY, JW .
MATHEMATICS OF COMPUTATION, 1965, 19 (90) :297-&
[2]
Computed tomography and magnetic resonance imaging for noninvasive coronary angiography and plaque imaging - Current and potential future concepts [J].
Fayad, ZA ;
Fuster, V ;
Nikolaou, K ;
Becker, C .
CIRCULATION, 2002, 106 (15) :2026-2034
[3]
Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart [J].
Flohr, T ;
Ohnesorge, B .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2001, 25 (06) :907-923
[4]
LORENZ TM, 1997, COMPUTER ASSISTED RA, P209
[5]
Topology adaptive deformable surfaces for medical image volume segmentation [J].
McInerney, T ;
Terzopoulos, D .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (10) :840-850
[6]
PRESS, 1992, NUMERICAL RECIPES
[7]
SHECTER G, 2003, UNPUB P SPIE