Background-In an effort to reduce x-ray exposure, we developed a technique for transcatheter closure of atrial septal defects under echocardiographic guidance without fluoroscopy. To assess the efficiency of this procedure for routine use, we compared our initial results with those for the conventional procedure. Methods and Results-Twenty-two randomly selected patients (median age 18 years; range 2 to 66 years) with atrial septal defects (n=13) or patent foramen ovale (n=9) underwent cardiac catheterization for possible interventional defect closure with echocardiography as the only imaging tool. Median stretched diameter was 9 mm (range 6 to 26 mm); median left-to-right shunt over the atrial septal defects was Qp/Qs = 1.8 (range 1.5 to 2.6). An Amplatzer septal occluder was successfully implanted in 19 defects without fluoroscopy and in 3 with the help of radiography. After 1 month, complete defect closure was documented in all patients. Compared with the conventional procedure of a control group of 131 patients, procedure times were not significantly different (88 versus 100 minutes; P=0.09). However, the study group received significantly higher doses of propofol for sedation (9.9 versus 5.6 mg/kg body weight; P=0.002) owing to extended transesophageal echocardiography. Conclusions-In the majority of patients in whom transcatheter closure of interatrial communications with the Amplatzer septal occluder is possible, the procedure can be safely performed under echocardiographic guidance without fluoroscopy.
引用
收藏
页码:847 / 849
页数:3
相关论文
共 15 条
  • [1] Transcatheter closure as standard treatment for most interatrial defects:: experience in 200 patients treated with the Amplatzer™ Septal Occluder
    Berger, F
    Ewert, P
    Björnstad, PG
    Dähnert, I
    Krings, G
    Brilla-Austgenat, I
    Vogel, M
    Lange, PE
    [J]. CARDIOLOGY IN THE YOUNG, 1999, 9 (05) : 468 - 473
  • [2] Initial clinical results with the Amplatzer septal occluder - a self-centering double-disc device for the occlusion of atrial septal defects
    Berger, F
    Ewert, P
    Stiller, B
    Dahnert, I
    Krings, G
    Vogel, M
    Lange, PE
    [J]. ZEITSCHRIFT FUR KARDIOLOGIE, 1998, 87 (03): : 185 - 190
  • [3] Bjornstad PG, 1997, CARDIOL YOUNG, V7, P277
  • [4] Transcatheter closure of atrial septal defects under echocardiographic guidance without X-ray: initial experiences
    Ewert, P
    Daehnert, I
    Berger, F
    Kaestner, A
    Krings, G
    Vogel, M
    Lange, PE
    [J]. CARDIOLOGY IN THE YOUNG, 1999, 9 (02) : 136 - 140
  • [5] IMAGING AND SIZING OF ATRIAL SEPTAL-DEFECTS BY MAGNETIC-RESONANCE
    HOLMVANG, G
    PALACIOS, IF
    VLAHAKES, GJ
    DINSMORE, RE
    MILLER, SW
    LIBERTHSON, RR
    BLOCK, PC
    BALLEN, B
    BRADY, TJ
    KANTOR, HL
    [J]. CIRCULATION, 1995, 92 (12) : 3473 - 3480
  • [6] Per-catheter ASD closure
    Latson, LA
    [J]. PEDIATRIC CARDIOLOGY, 1998, 19 (01) : 86 - 93
  • [7] Two- and three-dimensional transesophageal echocardiography in patient selection and assessment of atrial septal defect closure by the new DAS-angel wings device - Initial clinical experience
    Magni, G
    Hijazi, ZM
    Pandian, NG
    Delabays, A
    Sugeng, L
    Laskari, C
    Marx, GR
    [J]. CIRCULATION, 1997, 96 (06) : 1722 - 1728
  • [8] 7-YEAR EXPERIENCE OF NONINVASIVE PREOPERATIVE DIAGNOSTICS IN CHILDREN WITH CONGENITAL HEART-DEFECTS - COMPREHENSIVE ANALYSIS OF 2,788 CONSECUTIVE PATIENTS
    MAREK, J
    SKOVRANEK, J
    HUCIN, B
    CHALOUPECKY, V
    TAX, P
    REICH, O
    SAMANEK, M
    [J]. CARDIOLOGY, 1995, 86 (06) : 488 - 495
  • [9] Masura J, 1997, CATHETER CARDIO DIAG, V42, P388, DOI 10.1002/(SICI)1097-0304(199712)42:4<388::AID-CCD7>3.0.CO
  • [10] 2-7