Experimental behaviour of recycled aggregate concrete filled steel tubular columns

被引:408
作者
Yang, You-Fu
Han, Lin-Hai [1 ]
机构
[1] Tsinghua Univ, Dept Civil Engn, Beijing 100084, Peoples R China
[2] Fuzhou Univ, Coll Civil Engn, Fujian 350002, Peoples R China
[3] Tsinghua Univ, China Educ Minist, Key Lab Struct Engn & Vibrat, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
recycled aggregate concrete filled steel tube (RACFST); recycled aggregate concrete (RAC); composite columns; composite action; ultimate strength; design codes;
D O I
10.1016/j.jcsr.2006.02.010
中图分类号
TU [建筑科学];
学科分类号
0813 [建筑学];
摘要
This paper describes a series of tests on steel tubular columns of circular and square section filled with normal concrete and recycled aggregate concrete. Thirty specimens, including 24 recycled aggregate concrete filled steel tubular (RACFST) columns and 6 normal concrete filled steel tubular (CFST) columns, were tested to investigate the influence of variations in the tube shape, circular or square, concrete type, normal concrete and recycled aggregate concrete, and load eccentricity ratio, from 0 to 0.53 on the performance of such composite columns. The test results show that both types of filled columns failed due to overall buckling. Comparisons are made with predicted ultimate strengths of RACFST columns using the existing codes, such as ACI 318-1999, AIJ-1997, AISC-LRFD-1999, BS5400-1979, DBJ13-51-2003 and EC4-1994. A theoretical model for normal CFST columns is adopted in this paper for RACFST columns. The predicted load versus deformation relationships are in good agreement with test results. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1310 / 1324
页数:15
相关论文
共 20 条
[1]
Material properties models for analysis of cold-formed steel members [J].
AbdelRahman, N ;
Sivakumaran, KS .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1997, 123 (09) :1135-1143
[2]
ACI, 1999, 31899 ACI
[3]
Influence of recycled aggregates on mechanical properties of HS/HPC [J].
Ajdukiewicz, A ;
Kliszczewicz, A .
CEMENT & CONCRETE COMPOSITES, 2002, 24 (02) :269-279
[4]
[Anonymous], 1999, Load and Resistance Factor Design Specification for Structural Steel Buildings
[5]
[Anonymous], 2003, 13512003 DBJ
[6]
Architectural Institute of Japan (AIJ), 1997, REC DES CONSTR CONCR
[7]
ASCCS, 1997, ASCCS SEM
[8]
*BRIT STAND I, 1979, BS5400 BRIT STAND 5
[9]
*DD ENV, 1994, 1994111994 DD ENV BR
[10]
Han L.H., 2001, STEEL COMPOS STRUCT, V1, P51, DOI DOI 10.12989/SCS.2001.1.1.051