A simple technique to characterize proximal and peripheral nitric oxide exchange using constant flow exhalations and an axial diffusion model

被引:142
作者
Condorelli, Peter
Shin, Hye-Won
Aledia, Anna S.
Silkoff, Philip E.
George, Steven C.
机构
[1] Univ Calif Irvine, Dept Biomed Engn, Irvine, CA 92697 USA
[2] Univ Calif Irvine, Dept Chem Engn & Mat Sci, Irvine, CA 92697 USA
[3] Univ Calif Irvine, Dept Med, Div Pulm & Crit Care, Irvine, CA 92697 USA
[4] Drexel Univ, Philadelphia, PA 19104 USA
关键词
model; airway; alveolar;
D O I
10.1152/japplphysiol.00533.2006
中图分类号
Q4 [生理学];
学科分类号
071003 [生理学];
摘要
The most common technique employed to describe pulmonary gas exchange of nitric oxide (NO) combines multiple constant flow exhalations with a two-compartment model (2CM) that neglects 1) the trumpet shape (increasing surface area per unit volume) of the airway tree and 2) gas phase axial diffusion of NO. However, recent evidence suggests that these features of the lungs are important determinants of NO exchange. The goal of this study is to present an algorithm that characterizes NO exchange using multiple constant flow exhalations and a model that considers the trumpet shape of the airway tree and axial diffusion (model TMAD). Solution of the diffusion equation for the TMAD for exhalation flows > 100 ml/s can be reduced to the same linear relationship between the NO elimination rate and the flow; however, the interpretation of the slope and the intercept depend on the model. We tested the TMAD in healthy subjects (n = 8) using commonly used and easily performed exhalation flows (100, 150, 200, and 250 ml/s). Compared with the 2CM, estimates (mean +/- SD) from the TMAD for the maximum airway flux are statistically higher (J'aw(NO) = 770 +/- 470 compared with 440 +/- 270 pl/s), whereas estimates for the steady-state alveolar concentration are statistically lower (CA(NO) = 0.66 +/- 0.98 compared with 1.2 +/- 0.80 parts/billion). Furthermore, CANO from the TMAD is not different from zero. We conclude that proximal (airways) NO production is larger than previously predicted with the 2CM and that peripheral (respiratory bronchioles and alveoli) NO is near zero in healthy subjects.
引用
收藏
页码:417 / 425
页数:9
相关论文
共 36 条
[1]
ALVING K, 1993, EUR RESPIR J, V6, P1368
[2]
ATS/ERS recommendations for standardized procedures for the online and offline measurement of exhaled lower respiratory nitric oxide and nasal nitric oxide, 2005 [J].
American Thoracic Society ;
European Respiratory Society .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2005, 171 (08) :912-930
[3]
Exhaled nitric oxide: A new lung function test [J].
Barnes, PJ ;
Kharitonov, SA .
THORAX, 1996, 51 (03) :233-237
[4]
Exhaled nitric oxide in the diagnosis of asthma: comparison with bronchial provocation tests [J].
Berkman, N ;
Avital, A ;
Breuer, R ;
Bardach, E ;
Springer, C ;
Godfrey, S .
THORAX, 2005, 60 (05) :383-388
[5]
BOUHUYS A, 1987, AM PHYSL SOC, P699
[6]
Characterizing airway and alveolar nitric oxide exchange during tidal breathing using a three-compartment model [J].
Condorelli, P ;
Shin, HW ;
George, SC .
JOURNAL OF APPLIED PHYSIOLOGY, 2004, 96 (05) :1832-1842
[7]
Prospective evaluation of the validity of exhaled nitric oxide for the diagnosis of asthma [J].
Dupont, LJ ;
Demedts, MG ;
Verleden, GM .
CHEST, 2003, 123 (03) :751-756
[8]
Alveolar and airway sites of nitric oxide inflammation in treated asthma [J].
Gelb, AF ;
Taylor, CF ;
Nussbaum, E ;
Gutierrez, C ;
Schein, A ;
Shinar, CM ;
Schein, MJ ;
Epstein, JD ;
Zamel, N .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2004, 170 (07) :737-741
[9]
Modeling pulmonary nitric oxide exchange [J].
George, SC ;
Hogman, M ;
Permutt, S ;
Silkoff, PE .
JOURNAL OF APPLIED PHYSIOLOGY, 2004, 96 (03) :831-839
[10]
Partitioning of alveolar and conducting airway nitric oxide in scleroderma lung disease [J].
Girgis, RE ;
Gugnani, MK ;
Abrams, J ;
Mayes, MD .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2002, 165 (12) :1587-1591