European experience with the Mosaic bioprosthesis

被引:49
作者
Eichinger, WB
Botzenhardt, F
Gunzinger, R
Kemkes, BM
Sosnowski, A
Maïza, D
Coto, EO
Bleese, N
机构
[1] Stadt Krankenhaus Munchen Bogenhausen, Munich, Germany
[2] Glenfield Gen Hosp, Leicester LE3 9QP, Leics, England
[3] CHR Cote De Nacre, Caen, France
[4] Clin Univ, Valencia, Spain
[5] Albertinen Krankenhaus, Hamburg, Germany
关键词
D O I
10.1067/mtc.2002.122552
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The purpose of this study was to prospectively evaluate the clinical and hemodynamic performance of the Mosaic bioprosthesis (Medtronic. Inc, Minneapolis, Minn). Methods: The stented porcine bioprosthesis combines the amino-oleic acid antimineralization treatment and the zero-pressure differential fixation technique for improved tissue durability. From February 1994 to May 1999, a total of 561 patients underwent Valve replacement with the Mosaic bioprosthesis at 5 centers in Europe: 461 in the aortic and 100 in the mitral position. There were 261 women and 300 men: mean age at implantation was 70 years (range, 23-89 years). Mean follow-up was 2.9 years grange. 0-6.2 years), with a total follow-up of 1710.1 patient-years. Results: Postoperative mortality was 4.2% per patient-year, including a valve-related mortality of 0.4% per patient-year. The freedom from event rates in the aortic position at 5 years and in the mitral position at 4 years were, respectively, 96.6% +/- 1.1% and 94.9% =/- 3.3% for primary thromboembolism, 96.4% +/- 5.0% and 87.1% +/- 4.8% for antithromboembolic-related hemorrhage, 99.1% +/- 0.5% and 100% for thrombosed prosthesis, 98.8% +/- 1.2% and 100% for structural valve deterioration, 98.8% +/- 0.7% and 100% for nonstructural dysfunction, 98.4% +/- 0.6% and 94.4% +/- 3.8% for endocarditis, and 95.4% +/- 1.6% and 95.3% +/- 3.7% for explant and reoperation. Mean pressure gradient values at 5 years ranged from 7.5 to 15.9 mm Hg in the aortic position and at 4 years from 2.0 to 6.9 mm Hg in the mitral position across all valve sizes. Conclusions: Clinical and hemodynamic performance of the Mosaic bioprosthesis were very satisfactory during the first 6 years after clinical introduction.
引用
收藏
页码:333 / 339
页数:7
相关论文
共 17 条
[1]   THE CARPENTIER-EDWARDS PERICARDIAL AORTIC-VALVE - INTERMEDIATE RESULTS IN 420 PATIENTS [J].
AUPART, M ;
NEVILLE, P ;
DREYFUS, X ;
MEURISSE, Y ;
SIRINELLI, A ;
MARCHAND, M .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1994, 8 (05) :277-280
[2]   Carpentier-Edwards pericardial valves in the mitral position: Ten-year follow-up [J].
Aupart, MR ;
Neville, PH ;
Hammami, S ;
Sirinelli, AL ;
Meurisse, YA ;
Marchand, MA .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1997, 113 (03) :492-498
[3]   BIOLOGICAL FACTORS AFFECTING LONG-TERM RESULTS OF VALVULAR HETEROGRAFTS [J].
CARPENTIER, A ;
LEMAIGRE, G ;
ROBERT, L ;
CARPENTIER, S ;
DUBOST, C ;
GERBODE, F .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1969, 58 (04) :467-+
[4]   MECHANISM OF EFFICACY OF 2-AMINO OLEIC-ACID FOR INHIBITION OF CALCIFICATION OF GLUTARALDEHYDE-PRETREATED PORCINE BIOPROSTHETIC HEART-VALVES [J].
CHEN, WL ;
SCHOEN, FJ ;
LEVY, RJ .
CIRCULATION, 1994, 90 (01) :323-329
[5]   In vivo hemodynamic, histologic, and antimineralization characteristics of the mosaic bioprosthesis [J].
Duarte, IG ;
MacDonald, MJ ;
Cooper, WA ;
Schmarkey, SL ;
Gott, JP ;
Brown, WM ;
Vinten-Johansen, J ;
Guyton, RA .
ANNALS OF THORACIC SURGERY, 2001, 71 (01) :92-99
[6]   Hemodynamic features of the freestyle aortic bioprosthesis compared with stented bioprosthesis [J].
Dumesnil, JG ;
LeBlanc, MH ;
Cartier, PC ;
Métras, J ;
Desaulniers, D ;
Doyle, DP ;
Lemieux, MD ;
Raymond, G .
ANNALS OF THORACIC SURGERY, 1998, 66 (06) :S130-S133
[7]   Guidelines for reporting morbidity and mortality after cardiac valvular operations [J].
Edmunds, LH ;
Clark, RE ;
Cohn, LH ;
Grunkemeier, GL ;
Miller, C ;
Weisel, RD .
ANNALS OF THORACIC SURGERY, 1996, 62 (03) :932-935
[8]  
Eichinger W, 2000, J HEART VALVE DIS, V9, P653
[9]   The mosaic bioprosthesis in the aortic position:: Hemodynamic performance after 2 years [J].
Eichinger, WB ;
Schütz, A ;
Simmerl, D ;
Gansera, BU ;
Breuer, M ;
Haslinger, B ;
Kemkes, BM .
ANNALS OF THORACIC SURGERY, 1998, 66 (06) :S126-S129
[10]   MEDTRONIC-INTACT PORCINE BIOPROSTHESIS - CLINICAL-PERFORMANCE TO 7 YEARS [J].
LEMIEUX, MD ;
JAMIESON, WRE ;
LANDYMORE, RW ;
DUMESNIL, JG ;
METRAS, J ;
MUNRO, AI ;
RAYMOND, G ;
TYERS, GFO ;
CARTIER, PC ;
ALI, IM ;
DESAULNIERS, D ;
DOYLE, D ;
DESPRES, JP ;
COTE, L ;
RICE, C ;
HENDERSON, C .
ANNALS OF THORACIC SURGERY, 1995, 60 (02) :S258-S263