The TRAC PS mobile-bearing prosthesis -: Design rationale and in vivo 3-dimensional laxity

被引:17
作者
Draganich, LF [1 ]
Pottenger, LA [1 ]
机构
[1] Univ Chicago, Sect Orthopaed Surg & Rehabil Med, Dept Surg, Chicago, IL 60637 USA
关键词
total knee arthroplasty; mobile-bearing; ligament balancing; laxity; quadriceps lever arm;
D O I
10.1016/S0883-5403(00)91363-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We present a posterior stabilized mobile-bearing prosthesis, TRAC PS, which has congruent contact from full extension to full flexion, allows for freedom of internal-external rotation, and has an automatic posterior shift in tibiofemoral contact on the tibia to maximize the quadriceps lever arm in flexion. TRAC PS has 2 radii of curvature in the sagittal plane, 1 for the distal femoral condyles and 1 for the posterior femoral condyles, as does the normal knee. The distal and posterior femoral condyles articulate congruently in the inner tracks or the outer tracks of the polyethylene bearing, respectively. Anterior or posterior sliding of the femoral condyles on the bearing or of the bearing on the tibial tray cannot occur, providing inherent anterior and posterior stability. Three-dimensional knee laxity testing was performed on 17 patients from 12 months to 25 months after total knee arthroplasty with the TRAC PS and on 18 healthy control subjects of similar ages. Normal ligament balancing and normal internal-external rotational laxity were achieved with the TRAC PS prosthesis. Anterior and posterior laxity in the patients with TRAC PS was significantly reduced compared with that of the control subjects.
引用
收藏
页码:102 / 112
页数:11
相关论文
共 73 条
[1]
Andriacchi T P, 1988, J Arthroplasty, V3 Suppl, pS13, DOI 10.1016/S0883-5403(88)80003-2
[2]
Andriacchi T P, 1986, J Arthroplasty, V1, P211, DOI 10.1016/S0883-5403(86)80033-X
[3]
A STUDY OF LOWER-LIMB MECHANICS DURING STAIR-CLIMBING [J].
ANDRIACCHI, TP ;
ANDERSSON, GBJ ;
FERMIER, RW ;
STERN, D ;
GALANTE, JO .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1980, 62 (05) :749-757
[4]
ANOUCHI YS, 1993, CLIN ORTHOP RELAT R, V287, P170
[5]
POLYETHYLENE WEAR IN MENISCAL KNEE REPLACEMENT - A ONE TO 9-YEAR RETRIEVAL ANALYSIS OF THE OXFORD KNEE [J].
ARGENSON, JN ;
OCONNOR, JJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (02) :228-232
[6]
THE EFFECT OF CONFORMITY, THICKNESS, AND MATERIAL ON STRESSES IN ULTRAHIGH MOLECULAR-WEIGHT COMPONENTS FOR TOTAL JOINT REPLACEMENT [J].
BARTEL, DL ;
BICKNELL, VL ;
WRIGHT, TM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (07) :1041-1051
[7]
Wear in retrieved condylar knee arthroplasties - A comparison of wear in different designs of 280 retrieved condylar knee prostheses [J].
Blunn, GW ;
Joshi, AB ;
Minns, RJ ;
Lidgren, L ;
Lilley, P ;
Ryd, L ;
Engelbrecht, E ;
Walker, PS .
JOURNAL OF ARTHROPLASTY, 1997, 12 (03) :281-290
[8]
BLUNN GW, 1991, CLIN ORTHOP RELAT R, P253
[9]
THE NEW-JERSEY LOW-CONTACT-STRESS KNEE REPLACEMENT SYSTEM - BIOMECHANICAL RATIONALE AND REVIEW OF THE 1ST 123 CEMENTED CASES [J].
BUECHEL, FF ;
PAPPAS, MJ .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1986, 105 (04) :197-204
[10]
CAMERON HU, 1994, CLIN ORTHOP RELAT R, P29