摘要
The review analysis of twenty two irrigation efficiency (IE) studies carried out in the Ebro River Basin shows that IE is low (average IE)(avg)(= 53%) in surface-irrigated areas with high-permeable and shallow soils inadequate for this irrigation system, high (IE)(avg)(= 79%) in surface-irrigated areas with appropriate soils for this system, and very high (IE)(avg)(= 94%) in modern, automated and well managed sprinkler-irrigated areas. The unitary salt (total dissolved solids) and nitrate loads exported in the irrigation return flows (IRF) of seven districts vary, depending on soil salinity and on irrigation and N fertilization management, between 3-16 Mg salt/ha-year and 23-195 kg NO)(3) N-/ha center dot year, respectively. The lower nitrate loads exported from high IE districts show that a proper irrigation design and management is a key factor to reduce off-site nitrogen pollution. Although high IE's also reduce off-site salt pollution, the presence of salts in the soil or subsoil may induce relatively high salt loads (>= 14 Mg/ha center dot year) even in high IE districts. Two important constrains identified in our revision were the short duration of most surveys and the lack of standards for conducting irrigation efficiency and mass balance studies at the irrigation district level. These limitations emphasize the need for the establishment of a permanent and standardized network of drainage monitoring stations for the appropriate off-site pollution diagnosis and control of irrigated agriculture.
引用
收藏
页码:451 / 461
页数:11
相关论文
共 32 条
[1]  
[Anonymous], 1998, OFF J EUR COMMUN L, V330, P32
[2]  
Aragues R., 2003, ENCY WATER SCI, P502, DOI [DOI 10.1081/E-EWS120010262, 10.1081/EEWS.120010262, DOI 10.1081/EEWS.120010262]
[3]  
BARRAGAN J, 2001, ESTUDIO ASPECTOS CUA
[4]  
BASSO L, 1994, THESIS U ZARAGOZA DE
[5]  
CANELA LI, 1991, RIEGOS DRENAJES, V50, P24
[6]   Salt and nitrate concentrations in the surface waters of the CR-V irrigation district (Bardenas I, Spain):: diagnosis and prescriptions for reducing off-site contamination [J].
Causapé, J ;
Quílez, D ;
Aragüés, R .
JOURNAL OF HYDROLOGY, 2004, 295 (1-4) :87-100
[7]  
CAUSAPE J, 2002, THESIS U ZARAGOZA DE
[8]  
CAUSAPE J, 2004, IN PRESS AGR WATER M
[9]  
Cavero J, 2003, J ENVIRON QUAL, V32, P916, DOI 10.2134/jeq2003.0916
[10]  
*CHE, 2001, UNP HIDR AG SUBT CUE