Three-dimensional protein map according to pI, hydrophobicity and molecular mass

被引:19
作者
Wall, DB [1 ]
Parus, SJ [1 ]
Lubman, DM [1 ]
机构
[1] Univ Michigan, Dept Chem, Ann Arbor, MI 48109 USA
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2002年 / 774卷 / 01期
关键词
pI; hydrophobicity; molecular mass; three-dimensional protein map; proteins;
D O I
10.1016/S1570-0232(02)00189-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A three-dimensional method has been developed to map the protein content of cells according to pI, M-w and hydrophobicity. The separation of complex protein mixtures from cells is performed using isoelectric focusing (IEF) in the liquid phase in the first dimension, non-porous silica (NPS) RP-HPLC in the second dimension and on-line electrospray ionization (ESI) time-of-flight mass spectrometry (TOF-MS) detection in the third dimension. The experimentally determined pI, M, and hydrophobicity can then be used to produce a three-dimensional map of the protein expression of a cell, where now each protein can be tagged by three independent parameters. The ESI-TOF-MS provides an accurate M. for the intact protein while the hydrophobicity dimension results from the RP-HPLC component of the separation. The elution time, or percent acetonitrile at time of elution, of the protein is related to the hyrophobicity, which is an inherent property of the protein. 3D protein maps can thus be generated showing pI, M-w and % acetonitrile at time of elution as well as pI, M, and hydrophobicity. The potential of the 3D plot for effective mapping of proteins from cells compared to current 2D methods is discussed. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:53 / 58
页数:6
相关论文
共 21 条
  • [1] New insights into cyclosporine A nephrotoxicity by proteome analysis
    Aicher, L
    Wahl, D
    Arce, A
    Grenet, O
    Steiner, S
    [J]. ELECTROPHORESIS, 1998, 19 (11) : 1998 - 2003
  • [2] Celis JE, 1999, ELECTROPHORESIS, V20, P300
  • [3] Chromatofocusing nonporous reversed-phase high-performance liquid chromatography/electrospray ionization time-of-flight mass spectrometry of proteins from human breast cancer whole cell lysates: a novel two-dimensional liquid chromatography/mass spectrometry method
    Chong, BE
    Yan, F
    Lubman, DM
    Miller, FR
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (04) : 291 - 296
  • [4] Giometti CS, 2000, ELECTROPHORESIS, V21, P2162
  • [5] Hoffmann P, 2001, PROTEOMICS, V1, P807, DOI 10.1002/1615-9861(200107)1:7<807::AID-PROT807>3.0.CO
  • [6] 2-6
  • [7] Jensen PK, 2000, ELECTROPHORESIS, V21, P1372, DOI 10.1002/(SICI)1522-2683(20000401)21:7<1372::AID-ELPS1372>3.0.CO
  • [8] 2-Y
  • [9] REGULATION OF MEGAKARYOCYTE PHENOTYPE IN HUMAN ERYTHROLEUKEMIA-CELLS
    LONG, MW
    HEFFNER, CH
    WILLIAMS, JL
    PETERS, C
    PROCHOWNIK, EV
    [J]. JOURNAL OF CLINICAL INVESTIGATION, 1990, 85 (04) : 1072 - 1084
  • [10] Mass spectrometry of proteins directly from polyacrylamide gels
    Loo, RRO
    Stevenson, TI
    Mitchell, C
    Loo, JA
    Andrews, PC
    [J]. ANALYTICAL CHEMISTRY, 1996, 68 (11) : 1910 - 1917