Improved targeting of pancreatic cancer: Experimental studies of a new bispecific antibody, pretargeting enhancement system for immunoscintigraphy

被引:28
作者
Cardillo, TM
Karacay, H
Goldenberg, DM
Yeldell, D
Chang, CH
Modrak, DE
Sharkey, RM
Gold, DV
机构
[1] Garden State Canc Ctr, Belleville, NJ 07109 USA
[2] IBC Pharmaceut Inc, Morris Plains, NJ USA
关键词
D O I
10.1158/1078-0432.CCR-03-0340
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The early detection and diagnosis of pancreatic cancer remains a major clinical challenge in which imaging procedures have a central role. The purpose of this study was to evaluate a pretargeting method with a bispecific PAM4 (bsPAM4; anti-MUC1) antibody for radioimmunoscintigraphy of experimental human pancreatic cancer. Experimental Design: A bispecific F(ab'), antibody was generated from chimeric PAM4 Fab' and murine 734 (anti-indium-diethylenetriaminepentaacetic acid) Fab' fragments and then used in conjunction with 2 peptide haptens (In-111-IMP-156 and Te-99m-IMP-192). Biodistribution studies and radioimmunoscintigraphic imaging properties of the radiolabeled bsPAM4, and pretargeted, radiolabeled peptides were examined in the CaPan1 human pancreatic tumor grown as s.c. xenografts in athymic nude mice. Tumor uptake and tumor:nontumor ratios were compared with a nontargeting irrelevant anti-CD20, bispecific rituximab, radiolabeled peptides alone, and with directly labeled PAM4. Results: Biodistribution results indicated significantly greater tumor uptake of radiolabeled peptides at 3 h after injection when pretargeting was performed with bsPAM4 as compared with the bispecific rituximab [20.2 +/- 5.5 percentage of injected dose per gram of tissue (%ID/g) versus 0.9 +/- 0.1%ID/g, respectively, for In-111-IMP-156., and 16.8 4.8%ID/g versus 1.1 +/- 0.2%ID/g, respectively, for 99-Tc-IMP-192]. Similar results were obtained at the 24-h time point. Tumor: nontumor ratios were > 30 for all of the tissues except the kidneys, where a ratio of 7.8 +/- 2.8 was observed. By immunoscintigraphy, tumors could be visualized as early as 30 min after injection of the radiolabeled peptide. Conclusions: These studies demonstrate the feasibility of using the pretargeted, bispecific antibody technology for nuclear imaging of pancreatic cancer. The advantage of pretargeted bsPAM4 antibody as an imaging platform is the high specificity for pancreatic cancer as compared with the physicochemical parameters identified by current imaging technologies.
引用
收藏
页码:3552 / 3561
页数:10
相关论文
共 84 条
[1]  
Adam BL, 2002, CANCER RES, V62, P3609
[2]  
*AM CANC SOC, 2003, CANC FACTS FIG, P16
[3]  
Andrianifahanana M, 2001, CLIN CANCER RES, V7, P4033
[4]   Endoscopic ultrasound and intraductal ultrasound in the diagnosis of small pancreatic tumors [J].
Ariyama, J ;
Suyama, M ;
Satoh, K ;
Wakabayashi, K .
ABDOMINAL IMAGING, 1998, 23 (04) :380-386
[5]  
Barbet J, 1998, J NUCL MED, V39, P1172
[6]   Reducing the renal uptake of radiolabeled antibody fragments and peptides for diagnosis and therapy: present status, future prospects and limitations [J].
Behr, TM ;
Goldenberg, DM ;
Becker, W .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1998, 25 (02) :201-212
[7]  
BEHR TM, 1998, TUMOR TARGET, V3, P32
[8]   Pancreatic ultrasonography [J].
Bennett, GL ;
Hann, LE .
SURGICAL CLINICS OF NORTH AMERICA, 2001, 81 (02) :259-+
[9]   THE PROGNOSTIC VALUE OF THE MONOCLONAL-ANTIBODIES HMFG1 AND HMFG2 IN BREAST-CANCER [J].
BERRY, N ;
JONES, DB ;
SMALLWOOD, J ;
TAYLOR, I ;
KIRKHAM, N ;
TAYLORPAPADIMITRIOU, J .
BRITISH JOURNAL OF CANCER, 1985, 51 (02) :179-186
[10]   POTENTIALLY RESECTABLE PANCREATIC ADENOCARCINOMA - SPIRAL CT ASSESSMENT WITH SURGICAL AND PATHOLOGICAL CORRELATION [J].
BLUEMKE, DA ;
CAMERON, JL ;
HRUBAN, RH ;
PITT, HA ;
SIEGELMAN, SS ;
SOYER, P ;
FISHMAN, EK .
RADIOLOGY, 1995, 197 (02) :381-385